DistributorSouthwire

Southwire

CU 600/1000V XLPE Insulation PVC AIA PVC Jacket XHHW-2. Teck - CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45360

{SQMTR_DUAL} SOUTHWIRE{R} {CSA} LL90458 3/C XXX AWG (XX{mm2}) CU TECK 90 XLPE -40{D}C FT4 AG14 SUN. RES. 90{D}C 1000V HL --- {UL} E96627 TYPE MC XLPE 600V SUN. RES. DIRECT BURIAL 90{D}C --- {NOM}-ANCE Tipo MC XHHW-2 CT FT4 600V o 1000V 90{D}C USA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Inner Jacket Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
8 AWG8 AWG770.1410.36451.14501.270.8462.15551.400.9562.43490729396179.626.717.02 64085399
1 AWG1 AWG19190.3220.82551.40501.271.5483.93651.651.6804.27163924392008910.8111.829.97 64088199
1/0 AWG1/0 AWG19190.3610.92551.40501.271.6324.15651.651.7644.481896282225341149.4012.331.24 64087899
3/0 AWG3/0 AWG19190.4561.16551.40501.271.8144.61651.651.9464.942643393340271826.6113.634.54 64088999
4/0 AWG4/0 AWG19190.5121.30551.40501.271.9434.94651.652.0755.273205477050782303.3414.536.83 64089899
350 KCMIL350 KCMIL37370.6611.68651.65601.522.3605.99802.032.5266.425020747184003810.1717.744.96 64090599
8 AWG8 AWG0.6530.970.7861.170.0330.050.0520.08 64085399
1 AWG1 AWG0.1280.190.1540.230.0190.030.0460.07 64088199
1/0 AWG1/0 AWG0.1020.150.1220.180.0170.030.0440.07 64087899
3/0 AWG3/0 AWG0.0640.100.0780.120.0140.020.0420.06 64088999
4/0 AWG4/0 AWG0.0510.080.0620.090.0130.020.0410.06 64089899
350 KCMIL350 KCMIL0.0310.050.0390.060.0120.020.0400.06 64090599

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionPackaging
640853998-7 3/C CU XLP BLACK/RED/BLUE TECK90 1KV AIA BLACK PVC JKT8 AWG 3C 7 STRCUT TO LENGTH REEL
640881991-19 3/C CU XLP TECK90 1KV AIA BLACK PVC JKT1 AWG 3C 19 STRCUT TO LENGTH REEL
640878991/0-19 3/C CU XLP TECK90 1KV AIA BLACK PVC JKT1/0 AWG 3C 19 STRCUT TO LENGTH REEL
640889993/0-19 3/C CU XLP TECK90 1KV AIA BLACK PVC JKT3/0 AWG 3C 19 STRCUT TO LENGTH REEL
640898994/0-19 3/C CU XLP TECK90 1KV AIA BLACK PVC JKT4/0 AWG 3C 19 STRCUT TO LENGTH REEL
64090599350-37 3/C CU XLP TECK90 1KV AIA BLACK PVC JKT350 KCMIL 3C 37 STRCUT TO LENGTH REEL

Application & features

For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, hazardous locations or direct buried. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.

  • -40°C - CSA Cold Bend and Impact Temperature
  • -40°C - Min. Installation Temperature
  • 90°C - Max. Continuous Operating Temperature

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
  • UL 1569 Metal-Clad Cables
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
  • CSA AG14 - Acid Gas Compliance
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test