CU 600/1000V XLPE Insulation 50% Ground AIA PVC Jacket XHHW-2. CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45309

Type MC Power Cable 600Volt Four Conductor Copper, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Three Bare CU 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (4) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG19190.3610.92551.401.3813.51501.271.4873.782058306327031226.0610.426.42 66539999
4/0 AWG4/0 AWG19190.5121.30551.401.8144.61601.521.9404.933773561554162456.6513.634.54 66540299
250 KCMIL250 KCMIL37370.5581.42651.651.9644.99601.522.0905.314343646364002902.9914.637.08 66541099
500 KCMIL500 KCMIL37370.7892.00651.652.5046.36751.912.6546.74828412328128005805.9818.647.24 95237499
1/0 AWG1/0 AWG0.1020.150.1220.180.0170.030.0440.07 66539999
4/0 AWG4/0 AWG0.0510.080.0620.090.0130.020.0410.06 66540299
250 KCMIL250 KCMIL0.0430.060.0530.080.0140.020.0410.06 66541099
500 KCMIL500 KCMIL0.0220.030.0290.040.0100.010.0390.06 95237499

Part numbers in this family (4)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
665399991/0-19 CU 4/C 55 MILS XHHW-2 3X6 CU GW AIA PVC 600V1/0 AWG 4C 19SBLACK/BLACK/BLACK/BLACKCUT TO LENGTH REEL
665402994/0-19 CU 4/C 55 MILS XHHW-2 3X4 CU GW AIA PVC 600V4/0 AWG 4C 19 STRBLACK/BLACK/BLACK/BLACKCUT TO LENGTH REEL
66541099250-37 CU 4/C 65 MILS XHHW-2 3X4 CU GW AIA PVC 600V250 KCMIL 4C 37SBLACK/BLACK/BLACK/BLACKCUT TO LENGTH REEL
95237499500-37 CU 4/C 65 MILS XHHW-2 3X1 CU GW AIA PVC 600V500 KCMIL 4C 37SBLACK/BLACK/BLACK/BLACKCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of op- erating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. The ground is sized to 50% of the phase conductor with three separate bare grounds one in each interstecie between condutors. Silicone Free.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy