DistributorSouthwire

Southwire

CU 600/1000V XLPE Insulation 50% Ground AIA PVC Jacket XHHW-2. CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45303

Type MC Power Cable 600Volt Three Conductor Copper, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Three Bare CU 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket with. Silicone Free.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (8) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG19190.3610.92551.401.2463.16501.271.3523.431677249625341149.409.524.13 65538399
2/0 AWG2/0 AWG19190.4051.03551.401.3543.44501.271.4603.711983295131941448.7710.225.91 66539699
3/0 AWG3/0 AWG19190.4561.16551.401.4493.68501.271.5553.952524375640271826.6110.927.69 65538699
250 KCMIL250 KCMIL37370.5581.42651.651.7694.49601.521.8894.803597535360002721.5513.233.53 67188399
350 KCMIL350 KCMIL37370.6611.68651.651.9835.04601.522.1035.344780711384003810.1714.737.34 57688899
500 KCMIL500 KCMIL37370.7892.00651.652.2755.78751.912.4256.1666299865120005443.1017.043.18 55259889
750 KCMIL750 KCMIL61610.9682.46802.032.7587.01751.912.9087.39975114511180008164.6620.451.82 58866699
1/0 AWG1/0 AWG0.1020.150.1220.180.0170.030.0440.07 65538399
2/0 AWG2/0 AWG0.0810.120.0970.140.0160.020.0430.06 66539699
3/0 AWG3/0 AWG0.0640.100.0780.120.0140.020.0420.06 65538699
250 KCMIL250 KCMIL0.0430.060.0530.080.0140.020.0410.06 67188399
350 KCMIL350 KCMIL0.0310.050.0390.060.0120.020.0400.06 57688899
500 KCMIL500 KCMIL0.0220.030.0290.040.0100.010.0390.06 55259889
750 KCMIL750 KCMIL0.0140.020.0220.030.0100.010.0380.06 58866699

Part numbers in this family (8)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
1/0 AWG (1)
655383991/0-19 CU 3/C 55 MILS XHHW-2 3X6 CU GW AIA PVC 600V1/0 AWG 3C 19 STRBLACK/BLACK/BLACKCUT TO LENGTH REEL
2/0 AWG (1)
665396992/0-19 CU 3/C 55 MILS XHHW-2 3X6 CU GW AIA PVC 600V2/0 AWG 3C 19 STRBLACK/BLACK/BLACKCUT TO LENGTH REEL
3/0 AWG (1)
655386993/0-19 CU 3/C 55 MILS XHHW-2 3X4 CU GW AIA PVC 600V3/0 AWG 3C 19 STRBLACK/BLACK/BLACKCUT TO LENGTH REEL
250 kcmil (1)
67188399250-37 CU 3/C 65 MILS XHHW-2 3X4 CU GW AIA PVC 600V250 KCMIL 3C 37SBLACK/BLACK/BLACKCUT TO LENGTH REEL
350 kcmil (1)
57688899350-37 CU 3/C 65 MILS XHHW-2 3X2 CU GW AIA PVC 600V350 KCMIL 3C 37 STRBLACK/BLACK/BLACKCUT TO LENGTH REEL
500 kcmil (2)
55259899500-37 CU 3/C 65 MILS XHHW-2 3X1 CU GW AIA PVC 600V500 KCMIL 3C 37SBLACK/BLACK/BLACKCUT TO LENGTH REEL
55259889500-37 CU 3/C 65 MILS XHHW-2 3X1 CU GW AIA PVC 600V 2000 FT500 KCMIL 3C 37SBLACK/BLACK/BLACK2000 FT REEL
750 kcmil (1)
58866699750-61 CU 3/C 80 MILS XHHW-2 3X2/0 CU GW AIA PVC 600V750 KCMIL 3C 61SBLACK/BLACK/BLACKCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of op- erating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. The ground is sized to 50% of the phase conductor with three separate bare grounds one in each interstecie between condutors. Silicone Free.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test