DistributorSouthwire

Southwire

CU 2000V NL-EPR RHH/RHW-2 Thermoset SOLONON LSZH-TS TRACTION POWER CABLE

Southwire #
SPEC48203

Traction Power Cable 2000 Volt Single Conductor Copper, No Lead Ethylene Propylene Rubber (NL-EPR) insulation RHH/RHW-2 Thermoset SOLONON® Low Smoke Zero Halogen (LSZH-TS) Jacket

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (13) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
1/0 AWG1/0 AWG1119190.3620.92651.65451.140.5981.52326485428637 64708399
350 KCMIL350 KCMIL1137370.6411.63751.91651.650.9442.401081160912961929 64448799
500 KCMIL500 KCMIL1137370.7661.95751.91651.651.0632.701544229817912665 89043377
500 KCMIL500 KCMIL1191910.7912.01751.91651.651.0882.761544229817982676 58582799
500 KCMIL500 KCMIL112592590.8502.16751.91651.651.1502.921548230418202708 56030599
500 KCMIL500 KCMIL114274270.9092.311052.67651.651.2713.231610239619612918 66972599
750 KCMIL750 KCMIL1161610.9682.46902.29651.651.2973.292316344726503944 89021177
750 KCMIL750 KCMIL111271270.9682.46902.29651.651.2973.292315344526503944 56358199
1000 KCMIL1000 KCMIL1161611.1182.84902.29651.651.4463.673088459534985206 55057999
1000 KCMIL1000 KCMIL111271271.1182.84902.29651.651.4503.683088459534685161 64708299
1/0 AWG1/0 AWG114.812.19854387.370.1020.150.1320.200.0330.05150150145145 64708399
350 KCMIL350 KCMIL117.619.3028001270.060.0310.050.0390.060.0400.06310310350350 64448799
500 KCMIL500 KCMIL118.521.5940001814.370.0220.030.0290.040.0390.06380380430430 89043377
500 KCMIL500 KCMIL118.722.1040001814.370.0220.030.0290.040.0390.06380380430430 58582799
500 KCMIL500 KCMIL119.223.3740001814.370.0220.030.0290.040.0390.06380380430430 56030599
500 KCMIL500 KCMIL1110.225.9140001814.370.0220.030.0290.040.0390.06380380430430 66972599
750 KCMIL750 KCMIL1110.326.1660002721.550.0140.020.0220.030.0380.06475475535535 89021177
750 KCMIL750 KCMIL1110.426.4260002721.550.0140.020.0220.030.0380.06475475535535 56358199
1000 KCMIL1000 KCMIL1111.629.4680003628.740.0110.020.0180.030.0370.06545545615615 55057999
1000 KCMIL1000 KCMIL1111.629.4680003628.740.0110.020.0180.030.0370.06545545615615 64708299

Part numbers in this family (13)

By size:
Southwire #DescriptionConstructionPackaging
1/0 AWG (1)
647083991/0-19 CU 65 NL-EPR/45 LSZH 2KV RHH/RHW-2 BLACK1/0 AWG 1C 19SCUT TO LENGTH REEL
350 kcmil (1)
64448799350-37 CU 75 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK350 KCMIL 1C 37SCUT TO LENGTH REEL
500 kcmil (6)
56030599500-259 CU 75 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK500 KCMIL 1C 259SCUT TO LENGTH REEL
89043399500-37 CU 75 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK500 KCMIL 1C 37SCUT TO LENGTH REEL
89043377500-37 CU 75 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK 0 FT500 KCMIL 1C 37SCUT TO LENGTH REEL
66972599500-427 CU 105 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK UL/CSA500 KCMIL 1C 427SCUT TO LENGTH REEL
58582799500-91 CU 75 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK500 KCMIL 1C 91SCUT TO LENGTH REEL
67131299500-91 CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK500 KCMIL 1C 91SCUT TO LENGTH REEL
750 kcmil (3)
56358199750-127 CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK750 KCMIL 1C 127SCUT TO LENGTH REEL
89021199750-61 CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK750 KCMIL 1C 61SCUT TO LENGTH REEL
89021177750-61 CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK 0 FT750 KCMIL 1C 61SCUT TO LENGTH REEL
1000 kcmil (2)
647082991000-127 CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK1000 KCMIL 1C 127SCUT TO LENGTH REEL
550579991000-61 CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK1000 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire 2000V No Lead NL-EPR/SOLONON Traction Power Cable is suited for use in mass transit and general industry applications where flexibility, fire resistance, and low smoke generation are a concern. May be installed in wet or dry locations in cable trays or raceways. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Resistance to moisture and most oils, acids, and alkalis with an overall durable LSZH XLPO jacket. Meets Flame Spread and Smoke Release requirements of NFPA 130. Rated for 1000 lb/ft maximum sidewall pressure. Alternate constructions available upon request.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • ASTM B173 Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (250kcmil & Larger)
  • AREMA 10.3.13 Recommended Design Criteria for Low-Smoke Halogen Free (LSHF) Polymeric Cable Jackets