DistributorSouthwire

Southwire

CU 2000V EPR Insulation Thermoset CPE-TS Jacket. RHH/RHW-2

Southwire #
SPEC45501

Power Cable 2000 Volt Single Conductor Copper, Ethylene Propylene Rubber (EPR) insulation RHH/RHW-2 Thermoset Chlorinated Polyethylene (CPE-TS) Jacket

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (5) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
6 AWG6 AWG11770.1780.45551.40300.760.3640.9281121126188 45717899
4/0 AWG4/0 AWG1119190.5121.30651.65451.140.7481.906539727881173 13854499
250 KCMIL250 KCMIL1137370.5421.38751.91651.650.8422.1477111479621432 13782899
500 KCMIL500 KCMIL1137 TCu37 TCu0.7892.00751.91651.651.0892.771543229617992677 67929199
1000 KCMIL1000 KCMIL1161611.1172.84902.29651.651.4493.683087459434715165 64156099
6 AWG6 AWG111.53.8120994.800.4110.610.4950.740.0510.0865657575 45717899
4/0 AWG4/0 AWG112.97.371692767.480.0510.080.0620.090.0410.06230230260260 13854499
250 KCMIL250 KCMIL113.48.642000907.180.0430.060.0530.080.0320.05255255290290 13782899
500 KCMIL500 KCMIL115.413.7240001814.370.0220.030.0290.040.0390.06380380430430 67929199
1000 KCMIL1000 KCMIL117.218.2980003628.740.0110.020.0180.030.0370.06545545615615 64156099

Part numbers in this family (5)

By size:
Southwire #DescriptionConstructionPackaging
457178996-7 CU RHH/RHW-2 EPR/CPE 2KV BLACK6 AWG 1C 7SCUT TO LENGTH REEL
138544994/0-19 TINNED CU RHH/RHW-2 NL-EPR/CPE 2KV BLACK4/0 AWG 1C 19SCUT TO LENGTH REEL
13782899250-37 CU RHH-RHW-2 CPE-TS 2KV BLACK250 KCMIL 1C 37SCUT TO LENGTH REEL
67929199500-37 TINNED CU RHH-RHW-2 2KV BLACK500 KCMIL 1C 37SCUT TO LENGTH REEL
641560991000-61 CU 90MILS EPR/65MILS CPE BLACK 2KV1000 KCMIL 0C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 2000 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • CT USE Sizes 1/0 AWG and Larger