Armorlite® Type MC XHHW-2 Copper Conductor Feeder Cable
- Southwire #
- SPEC60322
Copper XHHW-2 Insulated Singles. Bare Copper Grounding Conductor. UL Listed 600/1000 Volts. Rated VW-1. Lightweight Aluminum Interlocked Armor.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (2) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Color | Diameter Over Conductor (in)(cm) | Cond. Strands | Insulation Thickness (mils)(mm) | Ground Size | Diameter Over Armor (in)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 250 KCMIL250 KCMIL | 44 | PE,TN,PK,GY/OEPE,TN,PK,GY/OE | 0.5581.42 | 3737 | 701.78 | 1x2 GG1x2 GG | 1.9935.06 | 38915790 | 66929899 |
| 600 KCMIL600 KCMIL | 44 | BK,RD,BE,WEBK,RD,BE,WE | 0.8652.20 | 6161 | 802.03 | 1x350 GG1x350 GG | 2.8967.36 | 967414396 | 65371099 |
| 250 KCMIL250 KCMIL | 44 | 14.035.56 | 64002902.99 | 0.0430.06 | 0.0530.08 | 0.0410.06 | 204204 | 232232 | 66929899 |
| 600 KCMIL600 KCMIL | 44 | 20.351.56 | 153606967.17 | 0.0180.03 | 0.0250.04 | 0.0390.06 | 336336 | 380380 | 65371099 |
Part numbers in this family (2)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 66929899 | 250-4 STR CU XHHW-2 PURPLE/TAN/PINK/GRAY-ORANGE/#2 GREEN GROUND AIA MC 1000V 0 FT | 250 KCMIL 4C 37S | PUR/TAN/PNK/GRY-ORG/2 GRN GND | CUT TO LENGTH REEL | |
| 65371099 | 600-61 4/C CU XHHW BLACK/RED/BLUE/WHITE 350 GG AIA MC 600V 0 FT | 600 KCMIL 4C 61S | BLK/RED/BLU/WHT/350 GRN GND | CUT TO LENGTH REEL |
Application & features
Southwire Armorlite® Type MC Feeder Cable is suitable for use as follows:
- Feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22 (C).
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(E)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Binder tape with print legend wrapped around assembly.
- Type XHHW-2 rated 90ºC Wet or Dry.
Southwire Armorlite® Type MC Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1479 Standard for Safety Fire Tests of Penetration Firestops
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- RoHS-2 (European Directive 2011/65/EU)
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.