3/0-3 STR CU THHN BROWN/ORANGE/YELLOW/#3 GREEN GROUND AIA MC BLACK JKT
- Southwire #
- 58574799
Copper THHN/THWN-2 Insulated Singles. Green or Bare Copper Grounding Conductor. UL Listed. 600 Volts. Rated VW-1. Lightweight Aluminuml Interlocked Armor.
Part of the family: Armorlite® Type MC THHN/THWN Copper Conductor Feeder Cable 277/480V Colors
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Application & features
Southwire Armorlite® Type MC Feeder Cable is suitable for use as follows:
- Feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22 (C).
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(E)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Binder tape with print legend wrapped around assembly.
- Type THHN/THWN rated 90ºC Dry.
- Anti-short bushings are not required for use with MC cable per NEC and UL
Southwire Armorlite® Type MC Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Specifications
| Cond. Size | 3/0 AWG3/0 AWG |
|---|---|
| Conductor Number | 33 |
| Color | BN,OE,YW,GNBN,OE,YW,GN |
| Diameter Over Conductor | 0.456 inch1.16 cm |
| Cond. Strands | 1919 |
| Insulation Thickness | 60 mils1.52 mm |
| Ground Size | 1x31x3 |
| Diameter Over Armor | 1.573 inch4.00 cm |
| Jacket Thickness | 60 mils1.52 mm |
| Approx. OD | 1.699 inch4.32 cm |
| Approx. Weight | 2407 lbs/1000'3582 kgs/km |
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1479 Standard for Safety Fire Tests of Penetration Firestops
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- RoHS-2 (European Directive 2011/65/EU)
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.