Cond. SizeConductor NumberColorDiameter Over Conductor (in)(cm)Cond. StrandsInsulation Thickness (mils)(mm)Ground SizeDiameter Over Armor (in)(cm)Approx. Weight (lbs/1000')(kgs/km)
1/0 AWG1/0 AWG44BK,RD,BE,WE,GN,GN/YWBK,RD,BE,WE,GN,GN/YW0.3610.921919601.522x32x31.6774.2623773537 64683599
2/0 AWG2/0 AWG441-BK,2-RD,3-BE,WE,GN1-BK,2-RD,3-BE,WE,GN0.3951.001919601.521x61x61.5784.0122503348 45839899
4/0 AWG4/0 AWG55BK,RD,BE,WE,WE/BK,GNBK,RD,BE,WE,WE/BK,GN0.5121.301919601.521x41x41.9614.9841266140 67733899
250 KCMIL250 KCMIL44BK,RD,BE,WEBK,RD,BE,WE0.5581.423737701.781x21x21.9544.9639945944 64353799
250 KCMIL250 KCMIL55BK,RD,BE,WE,WE,GNBK,RD,BE,WE,WE,GN0.5581.423737701.781x41x42.1365.4347987140 56554599
350 KCMIL350 KCMIL44BK,BK,RD,RD,GNBK,BK,RD,RD,GN0.6611.683737701.781x2/01x2/02.3245.9056738442 59914499
600 KCMIL600 KCMIL44BK,RD,BE,WE,GNBK,RD,BE,WE,GN0.8652.206161802.031x21x22.7166.90870212950 57881799
1/0 AWG1/0 AWG4411.729.7227031226.060.1020.150.1220.180.0440.07120120136136 64683599
2/0 AWG2/0 AWG4411.027.9442591931.850.0810.120.1010.150.0430.06140140156156 45839899
4/0 AWG4/0 AWG5513.734.8067713071.270.0510.080.0620.090.0410.06184184182182 67733899
250 KCMIL250 KCMIL4413.734.8064002902.990.0430.060.0530.080.0410.06204204232232 64353799
250 KCMIL250 KCMIL551538.1080003628.740.0430.060.0530.080.0410.06204204203203 56554599
350 KCMIL350 KCMIL4416.341.40112005080.230.0310.050.0390.060.0400.06248248280280 59914499
600 KCMIL600 KCMIL441948.26192008708.970.0180.030.0250.040.0390.06336336380380 57881799

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
1/0 AWG · 4 conductors (1)
646835991/0-4 STR CU THHN BLK/RED/BLU/WHT/#3GRN/#1/0GRN-YEL AIA MC 600V 0 FT1/0 AWG 4C 19SBLK/RED/BLU/WHT/3 GRN GND/3 GRN-YLW GNDCUT TO LENGTH REEL
2/0 AWG · 4 conductors (1)
458398992/0-4 STR CU THHN 1-BLACK/2-RED/3-BLUE/WHITE/#6 GREEN GROUND AIA AIA MC600V 0 FT2/0 AWG 4C 19 STR1-BK/2-RD/3-BU/WHT/6 GRN GNDCUT TO LENGTH REEL
4/0 AWG · 5 conductors (1)
677338994/0-5 STR CU THHN BLACK/RED/BLUE/WHITE/WHITE-BLACK/#4 GREEN GROUND AIA MC 600V4/0 AWG 5C 19SBLK/RED/BLU/WHT/WHT-BLK/4 GRNGNDCUT TO LENGTH REEL
250 kcmil · 4 conductors (1)
64353799250-4 STR CU THHN BLACK/RED/BLUE/WHITE/#2 GREEN GROUND AIA MC 600V 0 FT250 KCMIL 4C 37SBLK/RED/BLU/WHT/2 GRN GND 0CUT TO LENGTH REEL
250 kcmil · 5 conductors (1)
56554599250-5 STR CU THHN BLACK/RED/BLUE/WHITE/WHITE/4 AWG GREEN GRND AIA MC250 KCMIL 5C 37SBLK/RED/BLU/WHT/WHT/4 GRN GND GND, 0CUT TO LENGTH REEL
350 kcmil · 4 conductors (2)
64325799350-4 STR CU THHN 1-BLK/2-BLK/1-RED/2-RED/#1 GREEN GROUND AIA MC 600V 0FT350 KCMIL 4C 37SBLK/BLK/RED/RED/1 GRN GND 0CUT TO LENGTH REEL
59914499350-4 STR CU THHN 1-BLK/2-BLK/1-RED/2-RED/#2/0 GREEN GROUND AIA MC 600V0 FT350 KCMIL 4C 37SBLK/BLK/RED/RED/2/0 GRN GNDD, 0CUT TO LENGTH REEL
600 kcmil · 4 conductors (2)
57881799600-4 STR CU THHN B/R/U/W #2GG AIA MC 600V 0 FT600 KCMIL 4C 61SBLK/RED/BLU/WHT/2 GRN GND 0CUT TO LENGTH REEL
67844799600-4 STR CU THHN BLACK/RED/BLUE/WHITE 600GG AIA MC BLACK JKT600 KCMIL 4C 61SBLK/RED/BLU/WHT/GRNCUT TO LENGTH REEL

Application & features

Southwire Armorlite® Type MC Feeder Cable is suitable for use as follows:
- Feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
- Where exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Suitable for Wet Location per NEC 330.10(A)(11)
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways, or as aerial cable on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Type THHN/THWN rated 90ºC Dry/ 75ºC Wet

Southwire Armorlite® Type MC Feeder Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.