Armorlite® Type MC THHN/THWN Aluminum Conductor Feeder Cable with Green Insulated Ground 120/208V Colors
- Southwire #
- SPEC60320
Aluminum THHN/THWN-2 Insulated Singles with 8000 series Triple E™ Aluminum Alloy. Green Insulated AlumaFlex™ Aluminum Alloy Grounding Conductor. UL Listed. 600 Volts. Rated VW-1. Lightweight Aluminum Interlocked Armor.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (5) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Color | Diameter Over Conductor (in)(cm) | Cond. Strands | Insulation Thickness (mils)(mm) | Ground Size | Diameter Over Armor (in)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 4/0 AWG4/0 AWG | 44 | BK,RD,BE,WE,GNBK,RD,BE,WE,GN | 0.4741.20 | 1919 | 601.52 | 1x21x2 | 1.7864.54 | 14292127 | 58089399 |
| 250 KCMIL250 KCMIL | 44 | BK,RD,BE,WE,GNBK,RD,BE,WE,GN | 0.521.32 | 2222 | 701.78 | 1x1/01x1/0 | 1.9785.02 | 17802649 | 59291399 |
| 350 KCMIL350 KCMIL | 44 | BK,RD,BE,WE,GNBK,RD,BE,WE,GN | 0.6151.56 | 3535 | 701.78 | 1x1/01x1/0 | 2.195.56 | 22623366 | 59803599 |
| 600 KCMIL600 KCMIL | 44 | BK,RD,BE,WEBK,RD,BE,WE | 0.8122.06 | 5858 | 802.03 | 1x2501x250 | 2.6886.83 | 36345408 | 55254399 |
| 4/0 AWG4/0 AWG | 44 | 12.531.75 | 40621842.49 | 0.0840.13 | 0.1000.15 | 0.0410.06 | 144144 | 164164 | 58089399 |
| 250 KCMIL250 KCMIL | 44 | 13.835.05 | 48002177.24 | 0.0710.11 | 0.0860.13 | 0.0410.06 | 164164 | 184184 | 59291399 |
| 350 KCMIL350 KCMIL | 44 | 15.338.86 | 84003810.17 | 0.0500.07 | 0.0620.09 | 0.0400.06 | 200200 | 224224 | 59803599 |
| 600 KCMIL600 KCMIL | 44 | 18.847.75 | 144006531.72 | 0.0290.04 | 0.0370.06 | 0.0390.06 | 272272 | 308308 | 55254399 |
Part numbers in this family (5)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 4/0 AWG (1) | |||||
| 58089399 | 4/0-3 STR 3E AL THHN BLACK/RED/BLUE 3/0 AL WHT NEUT #2GG AL MC 600VMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL # | 4/0 AWG 4C 19 STR | BLK/RED/BLU/WHT/2 GRN GND 0 | CUT TO LENGTH REEL | |
| 250 kcmil (2) | |||||
| 64073399 | 250-4 STR 3E AL THHN BLACK/RED/BLUE/WHITE/#1 GREEN GROUND AIA MC 600V 0FT | 250 KCMIL 4C 22 STR | BLK/RED/BLU/WHT/1 GRN GND 0 | CUT TO LENGTH REEL | |
| 59291399 | 250-4 STR 3E AL THHN BLACK/RED/BLUE/WHITE/#1/0 GREEN GROUND AIA MC 600V0 FT | 250 KCMIL 4C 22 STR | BLK/RED/BLU/WHT/1/0 GRN GNDD, 0 | CUT TO LENGTH REEL | |
| 350 kcmil (1) | |||||
| 59803599 | 350-4 STR 3E AL THHN BLACK/RED/BLUE/WHITE/#1/0 GREEN GROUND AIA MC 600V0 FT | 350 KCMIL 4C 35S | BLK/RED/BLU/WHT/1/0 GRN GNDD, 0 | CUT TO LENGTH REEL | |
| 600 kcmil (1) | |||||
| 55254399 | 600-4 STR 3E AL THWN-2 BLACK/RED/BLUE/WHITE/#250 BARE GROUND AIA MC 600V | 600 KCMIL 4C 58S | BLK/RED/BLU/WHT/ 250 BARE GND/0 | CUT TO LENGTH REEL | |
Application & features
Southwire Armorlite® Type MC Feeder cable is suitable for use as follows:
- Feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Environmental air-handling spaces per NEC 300.22 (C).
- Installation in cable tray and approved raceways, or as aerial cable on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(E)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Type THHN/THWN rated 90ºC Dry/ 75ºC Wet
Southwire Armorlite® Type MC Feeder Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Standards & references
- ASTM B800 8000 Series Aluminum Alloy Wire
- ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1479 Standard for Safety Fire Tests of Penetration Firestops
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.