DistributorSouthwire

Southwire

AL Compact 5/8kV NLEPR Insulation 133/100% IL SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46110

Type MV-105 Single Conductor Aluminum, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (10) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
2 AWG2 AWG770.2680.680.5361.361152.920.6401.63551.400.7902.01342509398180.539.423.882.56.35 56018299
1/0 AWG1/0 AWG10100.3360.850.6041.531152.920.6641.69551.400.8142.07377561633287.129.724.642.56.35 55995399
2/0 AWG2/0 AWG12120.3760.960.6441.641152.920.7041.79802.030.8842.25446664798361.9710.626.922.56.35 56011699
3/0 AWG3/0 AWG18180.4221.070.6911.761152.920.7511.91802.030.9312.365027471006456.3111.128.193.07.62 56013399
4/0 AWG4/0 AWG19190.4741.200.7431.891152.920.8032.04802.030.9832.505698471269575.6111.729.723.07.62 56013499
250 KCMIL250 KCMIL22220.5201.320.7962.021152.920.8562.17802.031.0362.636359451500680.3912.431.503.07.62 56013799
350 KCMIL350 KCMIL35350.6151.560.8922.271152.920.9522.42802.031.1322.8877711562100952.5413.534.293.58.89 56013599
500 KCMIL500 KCMIL35350.7351.871.0342.631152.921.0942.78802.031.2743.24990147330001360.7815.238.613.58.89 56014799
750 KCMIL750 KCMIL58580.9082.311.2063.061152.921.2663.22802.031.4463.671315195745002041.1617.343.944.010.16 56017999
1000 KCMIL1000 KCMIL58581.0602.691.0442.651152.921.1042.80802.031.5984.061627242160002721.5519.148.514.511.43 56018099
2 AWG2 AWG0.2670.400.3360.500.0360.050.0450.070.369 + j0.2720.369 + j0.2720.031 + j0.0380.031 + j0.03818771877115115125125150150165165 56018299
1/0 AWG1/0 AWG0.1680.250.2110.310.0300.040.0410.060.370 + j0.2590.370 + j0.2590.033 + j0.0340.033 + j0.03420882088150150160160200200225225 55995399
2/0 AWG2/0 AWG0.1330.200.1670.250.0280.040.0410.060.370 + j0.2590.370 + j0.2590.033 + j0.0340.033 + j0.03422122212170170185185230230260260 56011699
3/0 AWG3/0 AWG0.1050.160.1330.200.0250.040.0400.060.370 + j0.2590.370 + j0.2590.033 + j0.0340.033 + j0.03423542354195195210210270270300300 56013399
4/0 AWG4/0 AWG0.0840.130.1050.160.0230.030.0380.060.370 + j0.2590.370 + j0.2590.033 + j0.0340.033 + j0.03425152515225225245245310310350350 56013499
250 KCMIL250 KCMIL0.0710.110.0900.130.0220.030.0380.060.370 + j0.2590.370 + j0.2590.033 + j0.0340.033 + j0.03426832683250250270270345345385385 56013799
350 KCMIL350 KCMIL0.0500.070.0650.100.0190.030.0360.050.370 + j0.2590.370 + j0.2590.033 + j0.0340.033 + j0.03429772977305305325325430430480480 56013599
500 KCMIL500 KCMIL0.0350.050.0460.070.0160.020.0340.050.370 + j0.2720.370 + j0.2720.031 + j0.0380.031 + j0.03833493349370370400400545545605605 56014799
750 KCMIL750 KCMIL0.0240.040.0330.050.0140.020.0320.050.370 + j0.2890.370 + j0.2890.024 + j0.0320.024 + j0.03239163916470470505505710710790790 56017999
1000 KCMIL1000 KCMIL0.0180.030.0260.040.0120.020.0310.050.370 + j0.2890.370 + j0.2890.024 + j0.0320.024 + j0.03243874387545545590590855855950950 56018099

Part numbers in this family (10)

By size:
Southwire #DescriptionConstructionPackaging
560182992-7 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA2 AWG 1C 7SCUT TO LENGTH REEL
559953991/0-10 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA1/0 AWG 1C 10SCUT TO LENGTH REEL
560116992/0-12 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA2/0 AWG 1C 12SCUT TO LENGTH REEL
560133993/0-18 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL3/0 AWG 1C 18SCUT TO LENGTH REEL
560134994/0-19 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
56013799250-22 3E AL 115 MILS NL-EPR SIM-PVC CT 5KV 133%/8KV 100% BLACK UL/CSA 0 FT250 KCMIL 1C 22SCUT TO LENGTH REEL
56013599350-35 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA350 KCMIL 1C 35SCUT TO LENGTH REEL
56014799500-35 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA500 KCMIL 1C 35SCUT TO LENGTH REEL
56017999750-58 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA750 KCMIL 1C 58SCUT TO LENGTH REEL
560180991000-58 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA1000 KCMIL 1C 58SCUT TO LENGTH REEL

Application & features

Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661