DistributorSouthwire

Southwire

AL Compact 35kV NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46710

Type MV-105 Single Conductor Aluminum, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (9) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
1/0 AWG1/0 AWG10100.3360.851.2143.0842010.671.2743.24802.031.4543.699981485633287.1217.444.204.010.16 56699499
2/0 AWG2/0 AWG12120.3760.961.2543.1942010.671.3143.34802.031.4943.7910631582798361.9717.945.474.511.43 59062199
3/0 AWG3/0 AWG15150.4221.071.3013.3042010.671.3613.46802.031.5413.91114116981006456.3118.446.744.511.43 56699599
4/0 AWG4/0 AWG19190.4741.201.3533.4442010.671.4133.59802.031.5934.05123318351269575.6119.148.514.511.43 59119799
250 KCMIL250 KCMIL22220.5201.321.4063.5742010.671.4663.72802.031.6464.18132319691500680.3919.750.045.012.70 59119899
350 KCMIL350 KCMIL35350.6151.561.5023.8242010.671.5623.971102.791.8024.58161123972100952.5421.654.865.012.70 59119999
500 KCMIL500 KCMIL35350.7351.871.6444.1842010.671.7044.331102.791.9444.941899282630001360.7823.359.185.513.97 57817899
750 KCMIL750 KCMIL58580.9082.311.8164.6142010.671.8764.771102.792.1265.402339348145002041.1625.564.776.015.24 56699699
1000 KCMIL1000 KCMIL58581.0602.691.9685.0042010.672.0285.151102.792.2785.792722405160002721.5527.369.34 59778799
1/0 AWG1/0 AWG0.1680.250.2110.310.0670.100.0550.080.362 + j0.2290.362 + j0.2290.047 + j0.0450.047 + j0.04539783978155155165165200200225225 56699499
2/0 AWG2/0 AWG0.1330.200.1670.250.0620.090.0530.080.362 + j0.2640.362 + j0.2640.023 + j0.0320.023 + j0.03241024102175175190190230230260260 59062199
3/0 AWG3/0 AWG0.1050.160.1330.200.0580.090.0510.080.362 + j0.2640.362 + j0.2640.023 + j0.0320.023 + j0.03242444244200200215215270270300300 56699599
4/0 AWG4/0 AWG0.0840.130.1050.160.0540.080.0500.070.363 + j0.2290.363 + j0.2290.047 + j0.0440.047 + j0.04444054405230230245245310310345345 59119799
250 KCMIL250 KCMIL0.0710.110.0900.130.0510.080.0480.070.364 + j0.2430.364 + j0.2430.042 + j0.0460.042 + j0.04645734573250250270270345345380380 59119899
350 KCMIL350 KCMIL0.0500.070.0650.100.0460.070.0460.070.364 + j0.2430.364 + j0.2430.042 + j0.0460.042 + j0.04648674867305305330330430430475475 59119999
500 KCMIL500 KCMIL0.0350.050.0460.070.0410.060.0440.070.364 + j0.2430.364 + j0.2430.042 + j0.0460.042 + j0.04652395239370370400400530530590590 57817899
750 KCMIL750 KCMIL0.0240.040.0330.050.0350.050.0410.060.364 + j0.2430.364 + j0.2430.042 + j0.0460.042 + j0.04658065806455455490490685685765765 56699699
1000 KCMIL1000 KCMIL0.0180.030.0260.040.0310.050.0390.060.365 + j0.2690.365 + j0.2690.027 + j0.0360.027 + j0.03662776277525525565565825825920920 59778799

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionPackaging
566994991/0-10 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA1/0 AWG 1C 10SCUT TO LENGTH REEL
590621992/0-12 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL2/0 AWG 1C 12SCUT TO LENGTH REEL
566995993/0-15 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA3/0 AWG 1C 15SCUT TO LENGTH REEL
591197994/0-19 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
59119899250-22 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA250 KCMIL 1C 22SCUT TO LENGTH REEL
59119999350-35 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA350 KCMIL 1C 35SCUT TO LENGTH REEL
57817899500-35 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA500 KCMIL 1C 35SCUT TO LENGTH REEL
56699699750-58 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA750 KCMIL 1C 58SCUT TO LENGTH REEL
597787991000-58 3E AL 420 MILS NL-EPR 35KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA1000 KCMIL 1C 58SCUT TO LENGTH REEL

Application & features

Southwire’s 35KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661