DistributorSouthwire

Southwire

AL Compact 35kV NLEPR Insulation 100% IL Black SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46709

Type MV-105 Single Conductor Aluminum, 345 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (7) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
1/0 AWG1/0 AWG10100.3360.851.0642.703458.761.1242.85802.031.3043.318251228633287.1215.639.624.010.16 64955999
4/0 AWG4/0 AWG19190.4741.201.2033.063458.761.2633.21802.031.4433.67104315521269575.6117.343.944.010.16 58374199
250 KCMIL250 KCMIL22220.5201.321.2563.193458.761.3163.34802.031.4963.80112716771500680.3917.945.474.511.43 58089699
350 KCMIL350 KCMIL35350.6151.561.3523.433458.761.4123.59802.031.5924.04130319392100952.5419.148.514.511.43 64957299
500 KCMIL500 KCMIL35350.7351.871.4943.793458.761.5543.951102.791.7944.561667248130001360.7821.554.615.012.70 58089599
750 KCMIL750 KCMIL58580.9082.311.6664.233458.761.7264.381102.791.9664.992064307245002041.1623.559.695.513.97 59751199
1000 KCMIL1000 KCMIL58581.0602.691.8184.623458.761.8784.771102.792.1285.412451364760002721.5525.564.776.015.24 59778499
1/0 AWG1/0 AWG0.1680.250.2110.310.0600.090.0530.080.360 + j0.2640.360 + j0.2640.024 + j0.0340.024 + j0.03435133513155155165165200200225225 64955999
4/0 AWG4/0 AWG0.0840.130.1050.160.0480.070.0470.070.361 + j0.2500.361 + j0.2500.031 + j0.0380.031 + j0.03839413941230230245245310310345345 58374199
250 KCMIL250 KCMIL0.0710.110.0900.130.0460.070.0460.070.361 + j0.2500.361 + j0.2500.031 + j0.0380.031 + j0.03841084108250250270270345345380380 58089699
350 KCMIL350 KCMIL0.0500.070.0650.100.0400.060.0440.070.427 + j0.4210.427 + j0.4210.056 + j0.0340.056 + j0.03444024402305305330330430430475475 64957299
500 KCMIL500 KCMIL0.0350.050.0460.070.0360.050.0420.060.361 + j0.2500.361 + j0.2500.031 + j0.0380.031 + j0.03847744774370370400400530530590590 58089599
750 KCMIL750 KCMIL0.0240.040.0330.050.0310.050.0390.060.361 + j0.2500.361 + j0.2500.031 + j0.0380.031 + j0.03853415341455455490490685685765765 59751199
1000 KCMIL1000 KCMIL0.0180.030.0260.040.0270.040.0370.060.361 + j0.2640.361 + j0.2640.024 + j0.0340.024 + j0.03458125812525525565565825825920920 59778499

Part numbers in this family (7)

By size:
Southwire #DescriptionConstructionPackaging
649559991/0-10 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA1/0 AWG 1C 10SCUT TO LENGTH REEL
583741994/0-19 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
58089699250-22 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA250 KCMIL 1C 22SCUT TO LENGTH REEL
64957299350-35 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA350 KCMIL 1C 35SCUT TO LENGTH REEL
58089599500-35 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA500 KCMIL 1C 35SCUT TO LENGTH REEL
59751199750-58 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL750 KCMIL 1C 58SCUT TO LENGTH REEL
597784991000-58 3E AL 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA1000 KCMIL 1C 58SCUT TO LENGTH REEL

Application & features

Southwire’s 35KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661