DistributorSouthwire

Southwire

AL Compact 25kV NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46510

Type MV-105 Single Conductor Aluminum, 320 Mils No Lead Ethylene Propylene Rubber (NLEPR) 133% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (9) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
1/0 AWG1/0 AWG19190.3360.851.0142.583208.131.0742.73802.031.2543.197711147633287.1215.038.103.58.89 67150899
2/0 AWG2/0 AWG12120.3760.961.0542.683208.131.1142.83802.031.2943.298291234798361.9715.539.374.010.16 67201899
null AWGnull AWG 64943599
null KCMILnull KCMIL 64111399
500 KCMIL500 KCMIL34340.7351.871.4443.673208.131.5043.821102.791.7444.431593237130001360.7820.953.095.012.70 66504699
null KCMILnull KCMIL 56321099
750 KCMIL750 KCMIL53530.9082.311.6164.103208.131.6764.261102.791.9264.892005298445002041.1623.158.675.513.97 67202199
null KCMILnull KCMIL 64943299
1/0 AWG1/0 AWG0.1680.250.2110.310.0570.080.0520.080.492 + j0.5130.492 + j0.5130.128 + j0.0380.128 + j0.03833583358155155165165200200225225 67150899
2/0 AWG2/0 AWG0.1330.200.1670.250.0530.080.0500.070.492 + j0.5130.492 + j0.5130.128 + j0.0380.128 + j0.03834823482175175190190230230260260 67201899
null AWGnull AWG 64943599
null KCMILnull KCMIL 64111399
500 KCMIL500 KCMIL0.0350.050.0460.070.0340.050.0410.060.532 + j0.5060.532 + j0.5060.167 + j0.0370.167 + j0.03746194619370370400400530530590590 66504699
null KCMILnull KCMIL 56321099
750 KCMIL750 KCMIL0.0240.040.0330.050.0290.040.0390.060.494 + j0.4010.494 + j0.4010.128 + j0.0490.128 + j0.04951865186455455490490685685765765 67202199
null KCMILnull KCMIL 64943299

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionPackaging
1/0 AWG (1)
671508991/0-19 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA1/0 AWG 1C 19SCUT TO LENGTH REEL
2/0 AWG (1)
672018992/0-12 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA2/0 AWG 1C 12SCUT TO LENGTH REEL
4/0 AWG (2)
649435994/0-19 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S RED SIMpull PVC JACKET UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
672158994/0-19 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
350 kcmil (1)
64111399350-35 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK PVC UL/CSA350 KCMIL 1C 35SCUT TO LENGTH REEL
500 kcmil (1)
66504699500-34 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA500 KCMIL 1C 34SCUT TO LENGTH REEL
600 kcmil (1)
56321099600-36 3E AL 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA600 KCMIL 1C 36SCUT TO LENGTH REEL
750 kcmil (2)
67202199750-53 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA750 KCMIL 1C 53SCUT TO LENGTH REEL
64943299750-58 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S RED SIMpull PVC JACKET UL/CSA750 KCMIL 1C 58SCUT TO LENGTH REEL

Application & features

Southwire’s 25KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661