AL Compact 25kV NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
- Southwire #
- SPEC46510
Type MV-105 Single Conductor Aluminum, 320 Mils No Lead Ethylene Propylene Rubber (NLEPR) 133% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (9) ↓Available sizes & constructions
| Cond. Size | Cond. Strands | Diameter Over Conductor (in)(cm) | Diameter Over Insulation (in)(cm) | Insulation Thickness (mils)(mm) | Diameter Over Shield (in)(cm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | Max Pull Tension (lbs)(kg) | Min. Bend Radius (in)(cm) | Conduit Size (in)(cm) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1/0 AWG1/0 AWG | 1919 | 0.3360.85 | 1.0142.58 | 3208.13 | 1.0742.73 | 802.03 | 1.2543.19 | 7711147 | 633287.12 | 15.038.10 | 3.58.89 | 67150899 |
| 2/0 AWG2/0 AWG | 1212 | 0.3760.96 | 1.0542.68 | 3208.13 | 1.1142.83 | 802.03 | 1.2943.29 | 8291234 | 798361.97 | 15.539.37 | 4.010.16 | 67201899 |
| null AWGnull AWG | 64943599 | |||||||||||
| null KCMILnull KCMIL | 64111399 | |||||||||||
| 500 KCMIL500 KCMIL | 3434 | 0.7351.87 | 1.4443.67 | 3208.13 | 1.5043.82 | 1102.79 | 1.7444.43 | 15932371 | 30001360.78 | 20.953.09 | 5.012.70 | 66504699 |
| null KCMILnull KCMIL | 56321099 | |||||||||||
| 750 KCMIL750 KCMIL | 5353 | 0.9082.31 | 1.6164.10 | 3208.13 | 1.6764.26 | 1102.79 | 1.9264.89 | 20052984 | 45002041.16 | 23.158.67 | 5.513.97 | 67202199 |
| null KCMILnull KCMIL | 64943299 | |||||||||||
| 1/0 AWG1/0 AWG | 0.1680.25 | 0.2110.31 | 0.0570.08 | 0.0520.08 | 0.492 + j0.5130.492 + j0.513 | 0.128 + j0.0380.128 + j0.038 | 33583358 | 155155 | 165165 | 200200 | 225225 | 67150899 |
| 2/0 AWG2/0 AWG | 0.1330.20 | 0.1670.25 | 0.0530.08 | 0.0500.07 | 0.492 + j0.5130.492 + j0.513 | 0.128 + j0.0380.128 + j0.038 | 34823482 | 175175 | 190190 | 230230 | 260260 | 67201899 |
| null AWGnull AWG | 64943599 | |||||||||||
| null KCMILnull KCMIL | 64111399 | |||||||||||
| 500 KCMIL500 KCMIL | 0.0350.05 | 0.0460.07 | 0.0340.05 | 0.0410.06 | 0.532 + j0.5060.532 + j0.506 | 0.167 + j0.0370.167 + j0.037 | 46194619 | 370370 | 400400 | 530530 | 590590 | 66504699 |
| null KCMILnull KCMIL | 56321099 | |||||||||||
| 750 KCMIL750 KCMIL | 0.0240.04 | 0.0330.05 | 0.0290.04 | 0.0390.06 | 0.494 + j0.4010.494 + j0.401 | 0.128 + j0.0490.128 + j0.049 | 51865186 | 455455 | 490490 | 685685 | 765765 | 67202199 |
| null KCMILnull KCMIL | 64943299 |
Part numbers in this family (9)
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 1/0 AWG (1) | ||||
| 67150899 | 1/0-19 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA | 1/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 2/0 AWG (1) | ||||
| 67201899 | 2/0-12 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA | 2/0 AWG 1C 12S | CUT TO LENGTH REEL | |
| 4/0 AWG (2) | ||||
| 64943599 | 4/0-19 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S RED SIMpull PVC JACKET UL/CSA | 4/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 67215899 | 4/0-19 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA | 4/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 350 kcmil (1) | ||||
| 64111399 | 350-35 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK PVC UL/CSA | 350 KCMIL 1C 35S | CUT TO LENGTH REEL | |
| 500 kcmil (1) | ||||
| 66504699 | 500-34 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA | 500 KCMIL 1C 34S | CUT TO LENGTH REEL | |
| 600 kcmil (1) | ||||
| 56321099 | 600-36 3E AL 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA | 600 KCMIL 1C 36S | CUT TO LENGTH REEL | |
| 750 kcmil (2) | ||||
| 67202199 | 750-53 3E AL 320 MILS NL-EPR SIM-PVC 25KV 133% T/S BLACK JACKET UL/CSA | 750 KCMIL 1C 53S | CUT TO LENGTH REEL | |
| 64943299 | 750-58 3E AL 115 MILS NL-EPR 5KV 133%/8KV 100% T/S RED SIMpull PVC JACKET UL/CSA | 750 KCMIL 1C 58S | CUT TO LENGTH REEL | |
Application & features
Southwire’s 25KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.
Standards & references
- ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
- ASTM B836 Compact Rounded Stranded Aluminum Conductors
- UL 1072 Medium-Voltage Power Cables
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
- CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
- CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
- CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661