DistributorSouthwire

Southwire

AL 600V XLPE Insulation XHHW-2. CT Rated - Sunlight Resistant - Silicone Free

Southwire #
SPEC45007

Power Cable 600 or 1000 Volt Single Conductor Aluminum, Cross Linked Polyethylene (XLPE) insulation XHHW-2. CT Rated 1/0 and Larger - Sunlight Resistant - Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Approx. OD (inches)(cm)Aluminum Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
1/0 AWG1/0 AWG1110100.3360.85551.400.4581.1699147144214 56039799
250 KCMIL250 KCMIL1122220.5201.32651.650.6601.68235350313466 56036201
350 KCMIL350 KCMIL1135350.6151.56651.650.7561.92329490421627 56036301
750 KCMIL750 KCMIL1158580.9082.31802.031.0802.7470610518701295 56038199
1/0 AWG1/0 AWG111.84.57633287.120.1680.250.2010.300.0440.07120120135135 56039799
250 KCMIL250 KCMIL112.66.601500680.390.0710.110.0860.130.0410.06205205230230 56036201
350 KCMIL350 KCMIL113.07.622100952.540.0500.070.0620.090.0400.06250250280280 56036301
750 KCMIL750 KCMIL115.413.7245002041.160.0240.040.0310.050.0380.06385385435435 56038199

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionPackaging
1/0 AWG (1)
560397991/0 STR 3E AL (53.5mm2) XHHW-2 BLACK1/0 AWG 1C 10SCUT TO LENGTH REEL
250 kcmil (2)
56036299250 STR 3E AL (127mm2) XHHW-2 BLACK250 KCMIL 1C 22SCUT TO LENGTH REEL
56036201250 STR 3E AL (127mm2) XHHW-2 BLACK 2500 FT250 KCMIL 1C 22S2500 FT REEL
350 kcmil (2)
56036399350 STR 3E AL (177mm2) XHHW-2 BLACK350 KCMIL 1C 35SCUT TO LENGTH REEL
56036301350 STR 3E AL (177mm2) XHHW-2 BLACK 2500 FT350 KCMIL 1C 35S2500 FT REEL
750 kcmil (1)
56038199750 STR 3E AL (380mm2) XHHW-2 BLACK750 KCMIL 1C 58SCUT TO LENGTH REEL

Application & features

Southwire’s 600 or 1000 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. CT Rated 1/0 and Larger - Sunlight Resistant - Silicone Free

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • CT USE Sizes 1/0 AWG and Larger
  • VW-1 (Vertical-Wire) Flame Test