DistributorSouthwire

Southwire

AL 600V XLPE Insulation RHH/RHW-2/USE-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45008

Power Cable 600Volt Single Conductor Aluminum, Cross Linked Polyethylene (XLPE) insulation RHH/RHW-2/USE-2. CT Rated 1/0 and Larger - Sunlight Resistant - For Direct Burial - Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Approx. OD (inches)(cm)Aluminum Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
1/0 AWG1/0 AWG1110100.3360.85802.030.5041.2899147165246 57614299
4/0 AWG4/0 AWG1119190.4741.20802.030.6431.63199296293436 57599199
250 KCMIL250 KCMIL1135350.5201.32952.410.7201.83235350357531 57678799
350 KCMIL350 KCMIL1135350.6151.56952.410.8162.07329490471701 57613799
500 KCMIL500 KCMIL1135350.7351.87952.410.9362.38471701630938 56732499
750 KCMIL750 KCMIL1158580.9082.311102.791.1402.9070610519361393 57621999
1/0 AWG1/0 AWG112.05.08633287.120.1680.250.2010.300.0440.07120120135135 57614299
4/0 AWG4/0 AWG112.56.351269575.610.0840.130.1000.150.0410.06180180205205 57599199
250 KCMIL250 KCMIL112.87.111500680.390.0710.110.0860.130.0410.06205205230230 57678799
350 KCMIL350 KCMIL113.28.132100952.540.0500.070.0620.090.0400.06250250280280 57613799
500 KCMIL500 KCMIL113.79.4030001360.780.0350.050.0440.070.0390.06310310350350 56732499
750 KCMIL750 KCMIL115.714.4845002041.160.0240.040.0310.050.0380.06385385435435 57621999

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionPackaging
576142991/0 STR 3E AL USE-2 RHH-RHW-2 600V BLACK1/0 AWG 1C 10SCUT TO LENGTH REEL
575991994/0 STR 3E AL USE-2 RHH-RHW-2 600V BLACK4/0 AWG 1C 19SCUT TO LENGTH REEL
57678799250 STR 3E AL USE-2 RHH-RHW-2 600V BLACK250 KCMIL 1C 35SCUT TO LENGTH REEL
57613799350 STR 3E AL USE-2 RHH-RHW-2 600V BLACK350 KCMIL 1C 35SCUT TO LENGTH REEL
56732499500 STR 3E AL RHH-RHW-2 600V BLACK500 KCMIL 1C 34SCUT TO LENGTH REEL
57621999750 STR 3E AL USE-2 RHH-RHW-2 600V BLACK750 KCMIL 1C 58SCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. CT Rated 1/0 and Larger - Sunlight Resistant - For Direct Burial - Silicone Free

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.
  • VW-1 (Vertical-Wire) Flame Test