DistributorSouthwire

Southwire

AL 600/1000V XLPE Insulation PVC Jacket XHHW-2. CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45265

Type TC-ER Power Cable 600 or 1000 Volt Four Conductor Aluminum, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Polyvinyl Chloride (PVC) Jacket with 1 Bare AL Ground. Silicone Free.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (18) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Aluminum Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
3/0 AWG3/0 AWG4416160.4221.07551.40802.031.4463.67678100911771752 67225199
4/0 AWG4/0 AWG4419190.4741.20551.40802.031.5723.99868129214062092 58372799
250 KCMIL250 KCMIL4422220.5201.32651.651102.791.7894.541031153417452597 58212399
300 KCMIL300 KCMIL4421210.5691.45651.651102.791.9334.911204179219952969 67225201
350 KCMIL350 KCMIL4435350.6151.56651.651102.792.0455.191432213123273463 58212499
400 KCMIL400 KCMIL4435350.6591.67651.651102.792.1245.391601238325203750 57853799
500 KCMIL500 KCMIL4435350.7351.87651.651102.792.3105.871982295029724423 57853699
600 KCMIL600 KCMIL4458580.8122.06802.031102.792.6606.762363351737565590 45838399
750 KCMIL750 KCMIL4458580.9082.31802.031403.562.8587.262954439642966393 57853899
3/0 AWG3/0 AWG447.218.2932211461.020.1050.160.1260.190.0420.06124124140140 67225199
4/0 AWG4/0 AWG447.920.0740621842.490.0840.130.1000.150.0410.06144144164164 58372799
250 KCMIL250 KCMIL448.922.6148002177.240.0710.110.0860.130.0410.06164164184184 58212399
300 KCMIL300 KCMIL449.724.6457602612.690.0590.090.0710.110.0410.06184184208208 67225201
350 KCMIL350 KCMIL4412.331.2467203048.140.0500.070.0620.090.0400.06200200224224 58212499
400 KCMIL400 KCMIL4412.732.2676803483.590.0440.070.0540.080.0400.06216216244244 57853799
500 KCMIL500 KCMIL4413.935.3196004354.480.0350.050.0440.070.0390.06248248280280 57853699
600 KCMIL600 KCMIL4416.040.64115205225.380.0290.040.0370.060.0390.06272272308308 45838399
750 KCMIL750 KCMIL4417.143.43144006531.720.0240.040.0310.050.0380.06308308348348 57853899

Part numbers in this family (18)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
3/0 AWG (1)
672251993/0-16 4/C 3E AL XHHW-2/PVC PHASE ID 1x4 GW TYPE TC-ER 1000V BLACK 0 FT3/0 AWG 4C 16S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
4/0 AWG (1)
583727994/0-19 4/C 3E AL XHHW-2/PVC PHASE ID 1x2 GW TYPE TC-ER 1000V BLACK 0 FT4/0 AWG 4C 19 STR1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
250 kcmil (1)
58212399250-22 4/C 3E AL XHHW/PVC PHASE ID 1x1 GW TYPE TC-ER 1000V BLACK 0 FT250 KCMIL 4C 22 STR1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
300 kcmil (2)
67225299300-21 4/C 3E AL XHHW-2/PVC PHASE ID 1x2 GW TYPE TC-ER 1000V BLACK 0 FT300 KCMIL 4C 21S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
67225201300-21 4/C 3E AL XHHW-2/PVC PHASE ID 1x2 GW TYPE TC-ER 1000V BLACK 1000FT300 KCMIL 4C 21S1-BLACK/2-RED/3-BLUE/4-ORANGE1000 FT REEL
350 kcmil (1)
58212499350-35 4/C 3E AL XHHW/PVC PHASE ID 1x1/0 GW TYPE TC-ER 1000V BLACK 0 FT350 KCMIL 4C 35S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
400 kcmil (2)
57853799400-35 4/C 3E AL XHHW-2/PVC PHASE ID 1X#1 GW TYPE TC-ER 1000V BLACK 0 FT400 KCMIL 4C 35S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
58212199400-35 4/C 3E AL XHHW/PVC PHASE ID 1X#3/0 GW TYPE TC-ER 1000V BLACK 0 FT400 KCMIL 4C 35S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
500 kcmil (5)
57853699500-34 4/C 3E AL XHHW-2/PVC PHASE ID 1X#1 GW TYPE TC-ER 1000V BLACK 0 FT500 KCMIL 4C 34S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
58212599500-34 4/C 3E AL XHHW/PVC PHASE ID 1X#2/0 GW TYPE TC-ER 1000V BLACK 0 FT500 KCMIL 4C 34S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
58212699500-34 4/C 3E AL XHHW/PVC PHASE ID 1X#250 GW TYPE TC-ER 1000V BLACK 0 FT500 KCMIL 4C 34S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
59654999500-34 4/C 3E AL XHHW/PVC PHASE ID 1X#3/0 GW TYPE TC-ER 1000V BLACK 0 FT500 KCMIL 4C 34S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
66503899500-34 4/C 3E AL XHHW/PVC PINK/PURPLE/TAN/GRAY 1X#4/0 GG TYPE TC-ER 1000V BLACK 0 FT500 KCMIL 4C 34SPINK/PURPLE/TAN/GRAYCUT TO LENGTH REEL
600 kcmil (4)
45838399600-37 4/C 3E AL XHHW/PVC PHASE ID 1X#1 GW TYPE TC-ER 1000V BLACK600 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
58212799600-37 4/C 3E AL XHHW/PVC PHASE ID 1X#350 GW TYPE TC-ER 1000V BLACK 0 FT600 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
58225099600-37 4/C 3E AL XHHW/PVC PHASE ID 1X#4/0 GW TYPE TC-ER 1000V BLACK600 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL
58225001600-37 4/C 3E AL XHHW/PVC PHASE ID 1X#4/0 GW TYPE TC-ER 1000V BLACK 1000 FT600 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGE1000 FT REEL
750 kcmil (1)
57853899750-58 4/C 3E AL XHHW-2/PVC PHASE ID 1x1/0 GW TYPE TC-ER 1000V BLACK 0 FT750 KCMIL 4C 58S1-BLACK/2-RED/3-BLUE/4-ORANGECUT TO LENGTH REEL

Application & features

Southwire’s 600 or 1000 Volt Type TC-ER power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Silicone free.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy