AL 600/1000V XLPE Insulation AIA PVC Jacket XHHW-2. CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free
- Southwire #
- SPEC45313
Type MC Power Cable 600Volt Four Conductor Aluminum, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket with 1 Bare AL Ground. Silicone Free.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (5) ↓Available sizes & constructions
| Cond. Size | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Diameter Over Armor (in)(cm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | Max Pull Tension (lbs)(kg) | Min. Bend Radius (in)(cm) | |
|---|---|---|---|---|---|---|---|---|---|---|
| 250 KCMIL250 KCMIL | 2222 | 0.521.32 | 651.65 | 1.8874.79 | 651.65 | 2.0195.13 | 18692781 | 48002177.24 | 14.135.81 | 64465699 |
| 350 KCMIL350 KCMIL | 3535 | 0.6151.56 | 651.65 | 2.1185.38 | 651.65 | 2.2505.72 | 24323619 | 67203048.14 | 15.840.13 | 64465299 |
| 500 KCMIL500 KCMIL | 3535 | 0.7351.87 | 651.65 | 2.4086.12 | 802.03 | 2.5746.54 | 32324810 | 96004354.48 | 18.045.72 | 64464999 |
| 750 KCMIL750 KCMIL | 5858 | 0.9082.31 | 802.03 | 2.8967.36 | 802.03 | 3.0627.78 | 43566482 | 144006531.72 | 21.454.36 | 64098801 |
| 250 KCMIL250 KCMIL | 0.0710.11 | 0.0860.13 | 0.0150.02 | 0.0410.06 | 64465699 | |||||
| 350 KCMIL350 KCMIL | 0.0500.07 | 0.0620.09 | 0.0120.02 | 0.0400.06 | 64465299 | |||||
| 500 KCMIL500 KCMIL | 0.0350.05 | 0.0440.07 | 0.0100.01 | 0.0390.06 | 64464999 | |||||
| 750 KCMIL750 KCMIL | 0.0240.04 | 0.0310.05 | 0.0110.02 | 0.0380.06 | 64098801 |
Part numbers in this family (5)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 250 kcmil (1) | |||||
| 64465699 | 250-22 3E AL 4/C 65 MILS XHHW-2 1X1 3E AL GW AIA PVC 600V | 250 KCMIL 4C 22 STR | BLACK/BLACK/BLACK/BLACK | CUT TO LENGTH REEL | |
| 350 kcmil (1) | |||||
| 64465299 | 350-35 3E AL 4/C 65 MILS XHHW-2 1X2/0 3E AL GW AIA PVC 600V | 350 KCMIL 4C 35S | BLACK/BLACK/BLACK/BLACK | CUT TO LENGTH REEL | |
| 500 kcmil (1) | |||||
| 64464999 | 500-34 3E AL 4/C 65 MILS XHHW-2 1X2/0 3E AL GW AIA PVC 600V | 500 KCMIL 4C 34S | BLACK/BLACK/BLACK/BLACK | CUT TO LENGTH REEL | |
| 750 kcmil (2) | |||||
| 64098899 | 750-4 STR 3E AL XHHW-2 1-BLACK/2-RED/3-BLUE/4-ORANGE/#1/0 BARE GROUND AIA MC BLACK JKT | 750 KCMIL 4C 58S | 1-BK/2-RD/3-BU/4-OR/ 1/0 BAREGND | CUT TO LENGTH REEL | |
| 64098801 | 750-4 STR 3E AL XHHW-2 1-BLACK/2-RED/3-BLUE/4-ORANGE/#1/0 BARE GROUND AIA MC BLACK JKT 1500 FT | 750 KCMIL 4C 58S | 1-BK/2-RD/3-BU/4-OR/ 1/0 BAREGND | 1500 FT REEL | |
Application & features
Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Silicone Free.
Standards & references
- ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
- ASTM B836 Compact Rounded Stranded Aluminum Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1309 Marine Shipboard Cable
- UL 1569 Metal-Clad Cables
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
- ICEA S-58-679 Control Cable Conductor Identification Method 4
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy