DistributorSouthwire

Southwire

AL 600/1000V XLPE Insulation 50% Ground AIA PVC Jacket XHHW-2. CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45312

Type MC Power Cable 600Volt Three Conductor Aluminum, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Three Bare AL 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket with. Silicone Free.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (4) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
350 KCMIL350 KCMIL35350.6151.56651.651.9294.90651.652.0615.232081309763002857.6314.436.58 64933299
600 KCMIL600 KCMIL41410.8122.06802.032.4286.17802.032.5946.5932314808108004898.7918.045.72 67735399
750 KCMIL750 KCMIL58580.9082.31802.032.6246.66802.032.7907.0940716058135006123.4919.549.53 57622089
350 KCMIL350 KCMIL0.0500.070.0620.090.0120.020.0400.06 64933299
600 KCMIL600 KCMIL0.0290.040.0370.060.0120.020.0390.06 67735399
750 KCMIL750 KCMIL0.0240.040.0310.050.0110.020.0380.06 57622089

Part numbers in this family (4)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
350 kcmil (1)
64933299350-35 3E AL 3/C 65 MILS XHHW-2 3X2 3E AL GW AIA PVC 600V350 KCMIL 3C 35SBLACK/BLACK/BLACKCUT TO LENGTH REEL
600 kcmil (1)
67735399600-41 3E AL 3/C 80 MILS XHHW-2 3X1/0 3E AL GW AIA PVC 600V600 KCMIL 3C 41SBLACK/BLACK/BLACKCUT TO LENGTH REEL
750 kcmil (2)
57622099750-58 3E AL 3/C 80 MILS XHHW-2 3X2/0 3E AL GW AIA PVC 600V750 KCMIL 3C 58SBLACK/BLACK/BLACKCUT TO LENGTH REEL
57622089750-58 3E AL 3/C 80 MILS XHHW-2 3X2/0 3E AL GW AIA PVC 600V 2000 FT750 KCMIL 3C 58SBLACK/BLACK/BLACK2000 FT REEL

Application & features

Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of op- erating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. The ground is sized to 50% of the phase conductor with three separate bare grounds one in each interstecie between condutors. Silicone Free.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy