DistributorSouthwire

Southwire

600V CU PVC PAIRS ARMOR-X® PVC SPOS Instrumentation

Southwire #
SPEC43702

Type MC-HL Instrumentation Cable 600 Volt PVC/Nylon Insulated Singles Shielded Pairs with Overall Shield Continuous Corrugated Armor - ARMOR-X® -40°C to 90°C

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (20) ↓

Available sizes & constructions

Cond. SizeConductor NumberDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Min. Bend Radius (in)(cm)DC Resistance at 25C (ohms/1000')(ohms/km)
18 AWG18 AWG220.0450.11150.380.601.52601.520.7101.802133174.912.456.6699.92 89057289
18 AWG18 AWG440.0450.11150.380.701.78601.520.8202.082914335.7414.586.6699.92 89057389
18 AWG18 AWG880.0450.11150.380.922.34501.271.0402.644406557.218.296.6699.92 89057499
18 AWG18 AWG12120.0450.11150.381.022.59601.521.1462.915608338.020.326.6699.92 89057599
16 AWG16 AWG110.0560.14150.380.531.35601.520.6561.671842744.511.434.1816.22 89055989
16 AWG16 AWG220.0560.14150.380.651.65601.520.7701.962663965.313.464.1816.22 89056089
16 AWG16 AWG440.0560.14150.380.842.13601.520.9602.444056036.717.024.1816.22 89056189
16 AWG16 AWG880.0560.14150.381.022.59601.521.1462.915608338.020.324.1816.22 89056289
16 AWG16 AWG12120.0560.14150.381.223.10601.521.3463.4278911749.423.884.1816.22 89056389
16 AWG16 AWG16160.0560.14150.381.303.30601.521.4263.6295314189.925.154.1816.22 89056489
16 AWG16 AWG24240.0560.14150.381.473.73601.521.5964.051319196311.128.194.1816.22 89056589
181840.6640.660.09570.0957
161648.5148.510.08950.0895

Part numbers in this family (20)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
18 AWG · 4 conductors (2)
8905729918 2-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET18 AWG 4C 7 STRCUT TO LENGTH REEL
8905728918 2-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT18 AWG 4C 7 STR5000 FT REEL
18 AWG · 8 conductors (2)
8905739918 4-PR CU PVC/NYLON ARMOR-XTRA PVC 600V HL18 AWG 8C 7 STRCUT TO LENGTH REEL
8905738918 4-PR CU PVC/NYLON ARMOR-XTRA PVC 600V HL 5000 FT18 AWG 8C 7 STR5000 FT REEL
18 AWG · 16 conductors (1)
8905749918 8-PR CU PVC/NYLON ARMOR-X PVC 600V HL18 AWG 16C 7SLAYUP: (1/PR + 7/PR + 0) + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)CUT TO LENGTH REEL
18 AWG · 24 conductors (1)
8905759918 12-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET18 AWG 24C 7SLAYUP: {(0 + 3/PR + 0) + 9/PR} + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)CUT TO LENGTH REEL
16 AWG · 2 conductors (2)
8905599916 1-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 2C 7 STRB/WCUT TO LENGTH REEL
8905598916 1-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT16 AWG 2C 7 STRB/W5000 FT REEL
16 AWG · 4 conductors (2)
8905609916 2-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 4C 7 STRNONECUT TO LENGTH REEL
8905608916 2-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT16 AWG 4C 7 STRNONE5000 FT REEL
16 AWG · 8 conductors (2)
8905619916 4-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 8C 7SNONECUT TO LENGTH REEL
8905618916 4-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT16 AWG 8C 7SNONE5000 FT REEL
16 AWG · 16 conductors (2)
8905629916 8-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 16C 7SLAYUP: (1/PR + 7/PR + 0) + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)CUT TO LENGTH REEL
8905628916 8-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT16 AWG 16C 7SLAYUP: (1/PR + 7/PR + 0) + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)5000 FT REEL
16 AWG · 24 conductors (2)
8905639916 12-PAIR CU TFFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 24C 7SLAYUP: {(0 + 3/PR + 0) + 9/PR} + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)CUT TO LENGTH REEL
8905638916 12-PAIR CU TFFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT16 AWG 24C 7SLAYUP: {(0 + 3/PR + 0) + 9/PR} + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)5000 FT REEL
16 AWG · 32 conductors (2)
8905649916 16-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 32C 7SLAYUP: (0 + 5/PR) + 11/PR + MYLAR + DRAIN + FOIL (ALUMINUMSIDE IN)CUT TO LENGTH REEL
8905648916 16-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 2750 FT16 AWG 32C 7SLAYUP: (0 + 5/PR) + 11/PR + MYLAR + DRAIN + FOIL (ALUMINUMSIDE IN)2750 FT REEL
16 AWG · 48 conductors (2)
8905659916 24-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET16 AWG 48C 7SLAYUP: (2/PR CENTER + 8PR INNER + 14PR OUTER ) + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)CUT TO LENGTH REEL
8905658916 24-PAIR CU TFN ARMOR-XTRA MC-HL 600V BLACK PVC JACKET 5000 FT16 AWG 48C 7SLAYUP: (2/PR CENTER + 8PR INNER + 14PR OUTER ) + MYLAR + DRAIN + FOIL (ALUMINUM SIDE IN)5000 FT REEL

Application & features

Southwire’s Instrumentation Cables Type MC-HL ARMOR-X® per UL 1569 are suitable for installations as outlined in NEC Article 330 for process control and instrumentation, control circuits for operation and interconnection of protective and signaling devices and for general use in manufacturing, industrial and commercial distribution systems. Cables are constructed with 7-strand copper conductors insulated with nylon covered PVC. The paired conductors are colored black, white and alpha-numeric printed. Each pair has an aluminum polyester foil with 100% coverage and a tinned drain wire. The overall assembly is covered with an aluminum polyester foil with 100% coverage and a tinned drain wire. The cable is suited for use in cable trays, raceways, conduit, aerial (when supported with a messenger) and direct burial. The cable is rated for -40°C to 90°C and rated for Class I Div I hazardous locations. The inner jacket is black PVC with a nylon rip cord for easy removal. The outer jacket is black PVC. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.

Standards & references

  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 66 Fixture Wire
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method