600V CU EPR PAIRS CPE SPOS Instrumentation
- Southwire #
- SPEC43620
Type TC-ER Instrumentation Cable 600 Volt Tinned Copper Conductors EPR Insulated Singles Shielded Pairs with Overall Shield SPOS. CPE Jacket Heat, Moisture, Oil and Sunlight Resistant. Rated for -30°C to 90°C
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (5) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | Min. Bend Radius (in)(cm) | DC Resistance at 25C (ohms/1000')(ohms/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 18 AWG18 AWG | 44 | 0.0450.11 | 300.76 | 601.52 | 0.6581.67 | 175260 | 3.99.91 | 6.6699.92 | 59548099 |
| 16 AWG16 AWG | 22 | 0.0560.14 | 300.76 | 601.52 | 0.5731.46 | 134199 | 3.48.64 | 4.1816.22 | 59212199 |
| 16 AWG16 AWG | 44 | 0.0560.14 | 300.76 | 601.52 | 0.6971.77 | 252375 | 4.110.41 | 4.1816.22 | 59212399 |
| 16 AWG16 AWG | 1212 | 0.0560.14 | 300.76 | 802.03 | 1.0142.58 | 561835 | 6.015.24 | 4.1816.22 | 59212099 |
| 16 AWG16 AWG | 2424 | 0.0560.14 | 300.76 | 1102.79 | 1.3343.39 | 10771603 | 8.020.32 | 4.1816.22 | 59212599 |
| 1818 | 40.6640.66 | 0.09570.0957 | |||||||
| 1616 | 48.5148.51 | 0.08950.0895 |
Part numbers in this family (5)
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 59548099 | 18 4 PAIR UNLISTED/CPE POS TYPE TC 600V BLACK | 18 AWG 8C 7 STR | CUT TO LENGTH REEL | |
| 59212199 | 16 2 PAIR UNLISTED/CPE SPOS TYPE TC 600V BLACK | 16 AWG 4C 7 STR | CUT TO LENGTH REEL | |
| 59212399 | 16 4 PAIR UNLISTED/CPE SPOS TYPE TC 600V BLACK | 16 AWG 8C 7S | CUT TO LENGTH REEL | |
| 59212099 | 16 12 PAIR EPDM/CPE SPOS TYPE TC 600V BLACK 0 FT | 16 AWG 24C 7S | CUT TO LENGTH REEL | |
| 59212599 | 16 24 PAIR UNLISTED/CPE SPOS TYPE TC 600V BLACK | 16 AWG 48C 7S | CUT TO LENGTH REEL |
Application & features
Southwire’s Instrumentation Cables Type TC-ER per UL 1277 are suitable for installations as outlined in NEC Article 336 for process control and instrumentation, control circuits for operation and interconnection of protective and signaling devices and for general use in manufacturing, industrial and commercial distribution systems. Cables are constructed with 7-strand tinned copper conductors insulated with Ethylene Propylene Rubber EPR. The paired conductors are colored black, white, and alpha-numeric printed. Each pair has an aluminum polyester foil with 100% coverage and a tinned drain wire. The overall assembly is covered with an aluminum polyester foil with 100% coverage and a tinned drain wire. The cable is suited for use in cable trays, raceways, conduit, aerial (when supported with a messenger) and direct burial. The cable is rated for -30°C to 90°C wet or dry and rated for Class I Div II hazardous locations, sun and oil resistant. The jacket is black Chlorinated Polyeth- ylene CPE with a rip cord for easy removal
Standards & references
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1277 Electrical Power and Control Tray Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method