3/C CU 15KV Type SHD-GC RHINOSHIELDTM CPE Mining Cable 90°C. MSHA Approved
- Southwire #
- SPEC47361
Flexible Copper conductors, EPR 100% Insulation Level, Cu/Nylon Braid Shield, Extra Heavy Duty Two Layer Chlorinated Polyethylene (CPE) Jacket with Optional Reflective Stripes
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (1) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Diameter Over Insulation (in)(cm) | Ground Check Size | Inner Jacket Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 AWG2 AWG | 33 | 308308 | 0.3020.77 | 2105.33 | 0.7701.96 | 88 | 1052.67 | 1303.30 | 2.4106.12 | 32494835 | |
| 350 KCMIL350 KCMIL | 33 | 855855 | 0.8092.05 | 2155.46 | 1.2043.06 | 66 | 1303.30 | 1503.81 | 3.4308.71 | 832212385 | 59750999 |
| 2 AWG2 AWG | 0.1790.27 | 0.2260.34 | 0.0430.06 | 453205.48 | 19.248.77 | 164164 | |||||
| 350 KCMIL350 KCMIL | 0.0350.05 | 0.0460.07 | 0.0310.05 | 23941085.90 | 27.469.60 | 438438 | 59750999 |
Part numbers in this family (1)
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 59750999 | 350-855 TINNED CU 3/C 2x2/0GW 1x6GC SHD-GC RHINOSHIELD 15KV BLACK CPE JKT | 350 KCMIL 3C 855S | CUT TO LENGTH REEL |
Application & features
RHINOSHIELDTM Type SHD-GC is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers. It is also an ex- cellent choice for shovels, draglines, dredges, cranes and marine shore-to-ship power supplies, and anytime extra-durable, flexible cable is required. Suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C. For vertical drop requirements consult with factory application specialist.
Standards & references
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
- CSA C22.2 No. 96 Portable Power Cables
- ICEA S-75-381 Portable and Power Feeder Cables for Use in Mines
- CSA Listed File # LL65300 FT1, FT4, FT5 CSA C22.2, No. 96 Portable Power Cables
- MSHA listed: passes MSHA flame test
- Meets or exceeds ICEA requirements as applicable for ICEA S-75-381/NEMA WC 58, ASTM B-3