Números de parte en esta familia (27) ↓Tamaños y construcciones disponibles
| Tamaño Cond. | Número de Conductor | Hebras del Conductor | Diámetro Sobre Conductor (in)(cm) | Espesor del Aislamiento (mils)(mm) | Espesor de Cubierta (mils)(mm) | D.E. Aprox. (inches)(cm) | Peso Aprox. (lbs/1000')(kgs/km) | Resistencia en CC a 25C (ohms/1000')(ohms/km) | Radio de Curvatura Mín. (in)(cm) | |
|---|---|---|---|---|---|---|---|---|---|---|
| 14 AWG14 AWG | 22 | 77 | 0.0700.18 | 220.56 | 300.76 | 0.4671.19 | 112167 | 2.6313.92 | 1.64.06 | CL4Z142N0601 |
| 1818 | <30<30 | |||||||||
| 1616 | <30<30 | |||||||||
| 1414 | <30<30 | |||||||||
| 1818 | 22 | |||||||||
| 1818 | 44 | |||||||||
| 1818 | 88 | |||||||||
| 1616 | 22 | |||||||||
| 1616 | 44 | |||||||||
| 1616 | 88 | |||||||||
| 1414 | 22 | |||||||||
| 1414 | 44 | |||||||||
| 1414 | 88 | |||||||||
| 2 Black & White2 Black & White | 2 Black & White2 Black & White | 2 Black & White2 Black & White | ||||||||
| 3 Black & Green3 Black & Green | 3 Black & Green3 Black & Green | |||||||||
| 4 Black & Blue4 Black & Blue | 4 Black & Blue4 Black & Blue | |||||||||
| 5 Black & Yellow5 Black & Yellow | ||||||||||
| 6 Black & Brown6 Black & Brown | ||||||||||
| 7 Black & Orange7 Black & Orange | ||||||||||
| 8 Black & White8 Black & White |
Números de parte en esta familia (27)
| Núm. Southwire | Descripción | Construcción | Empaque | |
|---|---|---|---|---|
| CL4Z142N0608 | CL4SS 14/2 PARES CABLEADO CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 14/2 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z142N0605 | CL4SS 14/2 PARES CABLEADO CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 14/2 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z142N0601 | CL4SS 14/2 PARES CABLEADO CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 14/2 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z144N0608 | CL4SS 14/4 PARES CABLEADO CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 14/4 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z144N0605 | CL4SS 14/4 PARES CABLEADO CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 14/4 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z144N0601 | CL4SS 14/4 PARES CABLEADO CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 14/4 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z148N0608 | CL4SS 14/8 PARES CABLEADO CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 14/8 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z148N0605 | CL4SS 14/8 PARES CABLEADO CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 14/8 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z148N0601 | CL4SS 14/8 PARES CABLEADO CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 14/8 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z162N0608 | CL4SS 16/2 PAIR CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 16/2 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z162N0605 | CL4SS 16/2 PAIR CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 16/2 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z162N0601 | CL4SS 16/2 PAIR CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 16/2 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z164N0608 | CL4SS 16/4 PAIR CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 16/4 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z164N0605 | CL4SS 16/4 PAIR CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 16/4 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z164N0601 | CL4SS 16/4 PAIR CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 16/4 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z168N0608 | CL4SS 16/8 PAIR CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 16/8 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z168N0605 | CL4SS 16/8 PAIR CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 16/8 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z168N0601 | CL4SS 16/8 PAIR CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 16/8 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z182N0608 | CL4SS 18/2 PAIR CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 18/2 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z182N0605 | CL4SS 18/2 PAIR CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 18/2 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z182N0601 | CL4SS 18/2 PAIR CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 18/2 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z184N0608 | CL4SS 18/4 PAIR CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 18/4 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z184N0605 | CL4SS 18/4 PAIR CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 18/4 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z184N0601 | CL4SS 18/4 PAIR CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 18/4 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null | |
| CL4Z188N0608 | CL4SS 18/8 PAIR CU CL4Z/CMG PVC-LS NEGRO 1000 FT CL4SS 18/8 PAIR STR CU CL4Z/CMG PVC-LS BLACK 1000 FT | null null | null null | |
| CL4Z188N0605 | CL4SS 18/8 PAIR CU CL4Z/CMG PVC-LS VERDE 1000 FT CL4SS 18/8 PAIR STR CU CL4Z/CMG PVC-LS GREEN 1000 FT | null null | null null | |
| CL4Z188N0601 | CL4SS 18/8 PAIR CU CL4Z/CMG PVC-LS BLANCO 1000 FT CL4SS 18/8 PAIR STR CU CL4Z/CMG PVC-LS WHITE 1000 FT | null null | null null |
Aplicación y características
Destinado para su uso en Sistemas de Potencia Administrados por Fallo (FMPS), suministro remoto, circuitos de Clase 4 interiores de acuerdo con el Código Eléctrico Nacional (NEC) 2023 artículo 726. Para uso, principalmente, en agricultura, edificios inteligentes y densificación inalámbrica. La fuente de energía (transmisor) para circuitos de Clase 4 debe ser suministrada por una fuente de energía que tenga una salida de voltaje de 450 voltios (pico o CC) o menos. Los cables CL4Z se consideran solo para uso exterior y no deben estar adheridos ni usarse dentro de una estructura de edificio. Los cables tipo CL4Z cumplen con los requisitos aplicables para CL4. Los cables CMG pueden instalarse en edificios de acuerdo con el artículo 722.135 del NEC y la tabla 722.135(B).
Clasificaciones:
Temperatura de funcionamiento normal: 90°C
Rango de temperatura: -40°C a 90°C
Uso clasificado: Lugares secos o húmedos
Normas y referencias
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 1400-2 Fault-Managed Power Systems - Part 2: Requirements for Cables
- UL 444 Communications Cables
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test