Tamaños y construcciones disponibles
| Tamaño (kcmil¹)(mm^2) | Diámetro del Conductor (inches)(mm) | Espesor del Aislamiento (inch)(cm) | Diámetro Sobre Aislamiento (inch)(cm) | Diámetro de Cubierta General (inch)(cm) | Radio de Curvatura Mín. (inch)(inch) | Capacitancia | Corriente de Carga (A/kft) | Peso del Cable² (lbs/ft) | Forro de 30 mil Cortocircuito @ 0.5s (kA) | Peso del Cable² (lbs/ft) | Forro de 30 mil Cortocircuito @ 0.5s (kA) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 50012.70 | 0.741.88 | 354899.16 | 1.543.91 | 2.195.56 | 43/3343/33 | 65.8765.87 | 0.990.99 | 3.473.47 | 24.7024.70 | 2.032.03 | 24.7024.70 | |
| 75019.05 | 0.912.31 | 354899.16 | 1.714.34 | 2.396.07 | 44/2944/29 | 76.0176.01 | 1.141.14 | 4.484.48 | 27.1027.10 | 2.472.47 | 27.1027.10 | |
| 100025.40 | 1.062.69 | 354899.16 | 1.884.78 | 2.596.58 | 47/3247/32 | 85.6085.60 | 1.291.29 | 5.485.48 | 29.4029.40 | 2.902.90 | 29.4029.40 | |
| 125031.75 | 1.193.02 | 354899.16 | 2.005.08 | 2.746.96 | 50/3350/33 | 93.1393.13 | 1.401.40 | 6.376.37 | 31.2031.20 | 3.263.26 | 31.2031.20 | |
| 150038.10 | 1.323.35 | 354899.16 | 2.135.41 | 2.897.34 | 52/3552/35 | 100.69100.69 | 1.511.51 | 7.327.32 | 32.9032.90 | 3.653.65 | 32.9032.90 | |
| 175044.45 | 1.433.63 | 354899.16 | 2.265.74 | 3.057.75 | 55/3755/37 | 108.23108.23 | 1.631.63 | 8.308.30 | 34.8034.80 | 4.084.08 | 34.8034.80 | |
| 200050.80 | 1.503.81 | 354899.16 | 2.355.97 | 3.147.98 | 57/3857/38 | 113.10113.10 | 1.701.70 | 9.189.18 | 35.9035.90 | 4.394.39 | 35.9035.90 | |
| 250063.50 | 1.814.60 | 5001270.00 | 3.007.62 | 3.889.86 | 78/5878/58 | 100.20100.20 | 1.511.51 | 12.2012.20 | 42.7042.70 | 6.806.80 | 42.7042.70 | |
| 300076.20 | 1.975.00 | 5001270.00 | 3.168.03 | 4.0610.31 | 81/6181/61 | 106.73106.73 | 1.601.60 | 13.9013.90 | 44.8044.80 | 7.507.50 | 44.8044.80 | |
| 350088.90 | 2.075.26 | 5001270.00 | 3.268.28 | 4.1910.64 | 84/6384/63 | 110.93110.93 | 1.671.67 | 16.0016.00 | 46.1046.10 | 8.208.20 | 46.1046.10 | |
| 4000101.60 | 2.245.69 | 5001270.00 | 3.438.71 | 4.3911.15 | 88/6688/66 | 117.88117.88 | 1.771.77 | 18.3018.30 | 48.3048.30 | 9.109.10 | 48.3048.30 | |
| 5000127.00 | 2.496.32 | 5001270.00 | 3.689.35 | 4.6711.86 | 93/7093/70 | 128.02128.02 | 1.921.92 | 22.4022.40 | 51.6051.60 | 10.7010.70 | 51.6051.60 | |
| 6000152.40 | 2.676.78 | 5001270.00 | 3.869.80 | 4.8912.42 | 98/7398/73 | 135.54135.54 | 2.042.04 | 25.9025.90 | 52.7052.70 | 11.2011.20 | 52.7052.70 | |
| 50012.70 | 600600 | 7272 | 520520 | 6262 | 470470 | 5656 | 410410 | 4949 | ||||
| 75019.05 | 750750 | 9090 | 640640 | 7676 | 590590 | 7171 | 510510 | 6161 | ||||
| 100025.40 | 870870 | 104104 | 740740 | 8888 | 690690 | 8282 | 590590 | 7171 | ||||
| 125031.75 | 970970 | 116116 | 820820 | 9898 | 780780 | 9393 | 660660 | 7979 | ||||
| 150038.10 | 10601060 | 127127 | 890890 | 106106 | 860860 | 103103 | 720720 | 8686 | ||||
| 175044.45 | 11301130 | 135135 | 950950 | 114114 | 920920 | 110110 | 780780 | 9393 | ||||
| 200050.80 | 12001200 | 143143 | 10001000 | 120120 | 990990 | 118118 | 820820 | 9898 | ||||
| 250063.50 | 14201420 | 170170 | 12001200 | 143143 | 11301130 | 135135 | 960960 | 115115 | ||||
| 300076.20 | 15401540 | 184184 | 13001300 | 155155 | 12501250 | 149149 | 10501050 | 125125 | ||||
| 350088.90 | 16301630 | 195195 | 13801380 | 165165 | 13401340 | 160160 | 11301130 | 135135 | ||||
| 4000101.60 | 17101710 | 204204 | 14501450 | 173173 | 14301430 | 171171 | 12001200 | 143143 | ||||
| 5000127.00 | 18701870 | 223223 | 15701570 | 188188 | 16101610 | 192192 | 13501350 | 161161 | ||||
| 6000152.40 |
Aplicación y características
Se utiliza predominantemente para transmisión subterránea en sistemas de tubo conduit, adecuado para uso en lugares húmedos o secos, enterramiento directo, ductos subterráneos y donde esté expuesto a la luz solar. Debe utilizarse a 69,000 voltios o menos y a temperaturas del conductor que no excedan 90°C para operación normal.
Normas y referencias
- Max Voltage Rating: 72.5 kV
- BIL Rating: 350 kV
- Nominal Conductor: 90 °C
- Nominal Conductor: 90 °C
- Max. Emergency Conductor: 105 °C
- Short Circuit Conductor: 250 °C
- Minimum Installation: -10 °C
- Design Standards: AEIC, ICEA, IEC
- Factory Test Voltages: 80 kV / 60 min.
- XLPE Loss Factor: 0.0005
- Relative Permittivity: 2.3