DistributorSouthwire

Southwire

Titan2™ Type HC Liquidtight Flexible Metal Conduit

Southwire #
SPEC60512

Hot/Cold Liquid-Tight Flexible Metal Conduit. UL/CSA Listed. Sunlight Resistant. Temperature Rated -40C to 105C

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (4) ↓

Available sizes & constructions

Cond. SizeDia. Over Inner Jacket (in)(cm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Min. Bend Radius (in)(cm)
1/2 Inch1/2 Inch0.6221.580.8202.0830456.516.51 55288201
3/4 Inch3/4 Inch0.8202.081.0302.6238578.521.59 55288301
1 Inch1 Inch1.0412.641.2903.28608913.033.02 55288401
InchInchInchInchInchInchLb/100ftLb/100ftInchInch
3/83/80.484/0.5040.484/0.5040.690/0.7100.690/0.71024243*3*
1/21/20.622/0.6420.622/0.6420.820/0.8400.820/0.840303044
3/43/40.820/0.8400.820/0.8401.030/1.0501.030/1.050383855
111.041/1.0661.041/1.0661.290/1.3151.290/1.315606088
1-1/41-1/41.380/1.4101.380/1.4101.630/1.6601.630/1.66080801010
1-1/21-1/21.575/1.6001.575/1.6001.865/1.9001.865/1.9001131131212
222.020/2.0452.020/2.0452.340/2.3752.340/2.3751491491616
2-1/22-1/22.480/2.5052.480/2.5052.840/2.8752.840/2.8751981982020
333.070/3.1003.070/3.1003.460/3.5003.460/3.5002652652424
3-1/23-1/23.500/3.5403.500/3.5403.960/4.0003.960/4.0003003002828
444.000/4.0404.000/4.0404.460/4.5004.460/4.5003103103232
3/83/855288101552881015528810455288104
1/21/25528820555288205
3/43/455288304552883045528830555288305
115528840455288404
1-1/41-1/455288602552886025528860455288604
1-1/21-1/255288702552887025528870455288704
2255288802552888025528880455288804
2-1/22-1/25528890255288902
335528890255288902
3-1/23-1/25528900255289002
445528920255289202

Part numbers in this family (4)

By size:
Southwire #DescriptionSizeLengthColor
1/2" (2)
552882011/2" TITAN METAL-FLEX CONDUIT TYPE HCL GRAY 100 FT1/2100GRAY
552882041/2" TITAN METAL-FLEX CONDUIT TYPE HCL GRAY 500 FT1/2500GRAY
3/4" (1)
552883013/4" TITAN METAL-FLEX CONDUIT TYPE HCL GRAY 100 FT3/4100GRAY
1" (1)
552884011" TITAN METAL-FLEX CONDUIT TYPE HCL GRAY 100 FT1100GRAY

Application & features

Titan2™ Type HC is suitable for the following installations:

  • For extreme temperature environments
  • For the installation and protection of electrical conductors in circuits of 600 Volts nominal, or less.
  • Where the conditions of installation, operation, or maintenance require flexibility or protection from liquids, vapors, solids, or weather
  • Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment
  • Exposed or concealed installations
  • Applications requiring movement, crossover connections, or tight bends
  • Permitted for equipment grounding in sizes 3/8" through 1-1/4" in lengths not exceeding 6 feet per NEC 250.118(6)
  • For flexible connections to swimming pool, spa, and hot tub motors per NEC® 680.21(A)(3) & 680.42(A)(1)
  • Electric signs and outline lighting supply and secondary-circuit conductors per NEC® 600.7, 600.31 (1000 volts or less) & 600.32 (over 1000 volts)
  • Floating building feeders and services per NEC® 553.7
  • Boatyards & Marinas in accordance with NEC® 555.13
  • Cranes & Hoists in accordance with NEC® 610.11(C)
  • For Elevator, Dumbwaiters, Escalators, Moving Walks, Wheel Chair Lifts & Stairway Chair Lifts in accordance with NEC® 620.21 (where expressly permitted)
  • Under raised floors in information technology equipment conductors and cables in accordance with NEC® 645.5 (D) & 645.5(D)(2)
  • Service entrance in lengths up to six feet per NEC® 230.43(15)
  • Electric signs and outline lighting supply and secondary-circuit per NEC 600.31 (1000 Volts or less) & NEC 600.32 (over 1000 Volts)
  • Approved for use in lengths longer than 6 feet per NEC® 356.10(5)

  • Hazardous location:
  • Class I, Div. 2 - NEC® 501.10(B)(2) and 501.30(B)
  • Class II, Div. 1 and 2 - NEC® 502.10(A)(2) and 502.30(B) and NEC 502.10(B)(2)
  • Class III, Div. 1 and 2 - NEC® 503.10(A)(2) and 503.30(B) and NEC 503.10(A)(2)

  • Titan2™ Type HC Features
  • A protective combination of thermoplastic materials formed into a conduit/raceway which seals out water, liquids, abrasives, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, non-concentrated fixed alkalines, petroleum oils, salt air and spray, and weather
  • Smooth interior for easy wire pulling
  • UV sunlight resistant jacket
  • Rated for temperature range of -30°C to 80°C , 60°C Oil (-22 to +176, 140°F Oil)
  • Accepts standard liquid-tight fittings for use with LFNC-B
  • Rated for direct burial applications including concrete encasement
  • Standards & references

    • UL 360 Liquidtight Flexible Steel Conduit
    • CSA 22.2 No. 56 Flexible metal conduit and liquid-tight flexible metal conduit
    • NFPA 70 (National Electrical Code), Article 350 - Liquidtight Flexible Metal Conduit