DistributorSouthwire

Service Wire

VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper

Service Wire #
SW-SERVICE-DRIVE-TRAY-2KV

Three copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type RHW-2) , phase identified and cabled together with suitable fillers and three symmetrical bare copper ground conductors. Cable core shielded with 5-mil copper tape, helically applied with 50% overlap for 100% coverage and double tape thickness throughout the cable. Standard construction with overall black PVC jacket. Available with ServiceCPE or EnviroPlus ® (LSZH) jacket. Available with tinned conductors and 50% grounds*.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (18) ↓

Available sizes & constructions

Size (AWG or Kcmil)(AWG or Kcmil)Strand (no.)(no.)Insulation Thickness (mils)(mm)Grounding Conductors (AWG)(AWG)Jacket Thickness (mils)(mm)Approx. Diameter Overall (in.)(mm)Approx. Net Weight (lb./1000')(kg/km)Ampacity (30°C ambient) 90°C Wet/Dry
141477601.52(3) #14(3) #14601.520.5514.02083102525 VFD2KTCP14/3
121277601.52(3) #14(3) #14601.520.5915.02453653030 VFD2KTCP12/3
101077601.52(3) #14(3) #14601.520.6416.32954394040 VFD2KTCP10/3
8877802.03(3) #14(3) #14601.520.7920.14156185555 VFD2KTCP8/3
6677802.03(3) #12(3) #12802.030.9123.16389497575 VFD2KTCP6/3
4477802.03(3) #12(3) #12802.031.0225.98431,2559595 VFD2KTCP4/3
3377802.03(3) #10(3) #10802.031.0727.21,0071,499115115 VFD2KTCP3/3
2277802.03(3) #10(3) #10802.031.1328.71,1771,752130130 VFD2KTCP2/3
111919952.41(3) #10(3) #10802.031.2732.31,4392,141145145 VFD2KTCP1/3
1/01/01919952.41(3) #10(3) #10802.031.3534.31,7032,534170170 VFD2KTCP1/03
2/02/01919952.41(3) #10(3) #10802.031.4536.82,0283,018195195 VFD2KTCP2/03
3/03/01919952.41(3) #8(3) #8802.031.5539.42,4813,692225225 VFD2KTCP3/03
4/04/01919952.41(3) #8(3) #81102.791.7444.23,0834,588260260 VFD2KTCP4/03
25025037371102.79(3) #8(3) #81102.791.8847.83,5535,287290290 VFD2KTCP250/3
35035037371102.79(3) #6(3) #61102.792.0953.14,7537,073350350 VFD2KTCP350/3
50050037371102.79(3) #6(3) #61102.792.3659.96,3969,518430430 VFD2KTCP500/3
60060061611253.17(3) #6(3) #61102.792.5865.57,57511,273475475 VFD2KTCP600/3
75075061611253.17(3) #4(3) #41403.562.8171.49,44114,050535535 VFD2KTCP750/3

Part numbers in this family (18)

By size:
Southwire #DescriptionConstructionStrandInsulation ThicknessGrounding ConductorsJacket ThicknessApprox. Diameter OverallApprox. Net WeightAmpacity (30°C ambient) 90°C Wet/Dry
VFD2KTCP14/3VFD2KTCP14/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 14 AWG 3C14 AWG 3C760(3) #14600.5520825
VFD2KTCP12/3VFD2KTCP12/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 12 AWG 3C12 AWG 3C760(3) #14600.5924530
VFD2KTCP10/3VFD2KTCP10/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 10 AWG 3C10 AWG 3C760(3) #14600.6429540
VFD2KTCP8/3VFD2KTCP8/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 8 AWG 3C8 AWG 3C780(3) #14600.7941555
VFD2KTCP6/3VFD2KTCP6/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 6 AWG 3C6 AWG 3C780(3) #12800.9163875
VFD2KTCP4/3VFD2KTCP4/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 4 AWG 3C4 AWG 3C780(3) #12801.0284395
VFD2KTCP3/3VFD2KTCP3/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 3 AWG 3C3 AWG 3C780(3) #10801.071,007115
VFD2KTCP2/3VFD2KTCP2/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 2 AWG 3C2 AWG 3C780(3) #10801.131,177130
VFD2KTCP1/3VFD2KTCP1/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 1 AWG 3C1 AWG 3C1995(3) #10801.271,439145
VFD2KTCP1/03VFD2KTCP1/03 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 1/0 AWG1/0 AWG1995(3) #10801.351,703170
VFD2KTCP2/03VFD2KTCP2/03 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 2/0 AWG2/0 AWG1995(3) #10801.452,028195
VFD2KTCP3/03VFD2KTCP3/03 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 3/0 AWG3/0 AWG1995(3) #8801.552,481225
VFD2KTCP4/03VFD2KTCP4/03 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 4/0 AWG4/0 AWG1995(3) #81101.743,083260
VFD2KTCP250/3VFD2KTCP250/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 250 kcmil 3C250 kcmil 3C37110(3) #81101.883,553290
VFD2KTCP350/3VFD2KTCP350/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 350 kcmil 3C350 kcmil 3C37110(3) #61102.094,753350
VFD2KTCP500/3VFD2KTCP500/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 500 kcmil 3C500 kcmil 3C37110(3) #61102.366,396430
VFD2KTCP600/3VFD2KTCP600/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 600 kcmil 3C600 kcmil 3C61125(3) #61102.587,575475
VFD2KTCP750/3VFD2KTCP750/3 VFD TRAY CABLE RHW-2/PVC, Shielded 2,000 Volt Copper 750 kcmil 3C750 kcmil 3C61125(3) #41402.819,441535

Application & features

Application

For use in VFD applications. Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2, Class III - Div 1 and 2. *Patented for use with ServiceDrive ® connector and termination kit.

Specifications

Voltage Rating2 kV (2,000 V)2 kV
CertificationsCSA, REACH, RoHS, Rockwell, UL, USACSA, REACH, RoHS, Rockwell, UL, USA

Standards & references

  • UL 44 and UL 1277, CSA C22.2 #230
  • NFPA 79 Flexible Motor Supply Cable
  • ICEA S-95-658/NEMA WC-70
  • Exposed Runs Rated (TC-ER)
  • Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202/CSA FT-4,
  • ICEA T-29-520 (210,000 BTU)
  • Two-hour Firewall
  • Temperature Rated at 90°C Wet/Dry
  • Sunlight Resistant, Gasoline and Oil Resistant II Jacket
  • Direct Burial
  • Color Code: Black and Numbered
  • RoHS Compliant
  • NEMA BABA 70901-2-2024 WC-02-03, WC-02-04, WC-02-05
  • *U.S. Patent No. 7,309,835