DistributorSouthwire

Service Wire

JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor

Service Wire #
SW-JACKETED-MC-2KV-4-CDRS

Four copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type RHW-2) , phase identified and cabled together with suitable fillers (when required) and bare copper grounding conductor. Cable core covered with mylar binder tape and aluminum or galvanized steel interlocked armor with overall black PVC jacket. Jacket available under armor and in colors. Available with EnviroPlus ® (LSZH) jacket.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (11) ↓

Available sizes & constructions

Size (AWG or Kcmil)(AWG or Kcmil)Strand (no.)(no.)Insulation Thickness (mils)(mm)Grounding Conductor (AWG)(AWG)Diameter Over Armor (in.)(mm)PVC Jacket Thickness (mils)(mm)Approx. Diameter Overall (in.)(mm)Approx. Net Weight Aluminum Armor (lb./1000')(kg/km)Approx. Net Weight Galvanized Armor (lb./1000')(kg/km)Ampacity (30°C ambient)(30°C ambient)
6677852.16881.0727.2501.271.1729.77781,1589241,3757575 AAP2K6/4
4477852.16881.2331.2501.271.3333.81,0341,5391,1951,7789595 AAP2K4/4
2277852.16661.3734.8501.271.4737.31,4692,1861,7372,585130130 AAP2K2/4
11771052.67661.5739.9601.521.6942.91,8492,7522,1523,203145145 AAP2K1/4
1/01/019191052.67661.6742.4601.521.7945.52,2043,2802,5313,767170170 AAP2K1/04
2/02/019191052.67441.7945.5601.521.9148.52,6723,9763,0364,518195195 AAP2K2/04
3/03/019191052.67441.8948.0601.522.0151.13,1794,7313,5545,289225225 AAP2K3/04
4/04/019191052.67442.0351.6601.522.1554.63,8225,6884,2316,296260260 AAP2K4/04
25025037371203.05442.2156.1601.522.3359.24,5706,8015,0117,457290290 AAP2K250/4
35035037371203.05332.4361.7751.912.5865.56,1259,1156,6269,861350350 AAP2K350/4
50050037371203.05222.7369.3751.912.8873.28,31612,3768,88713,225430430 AAP2K500/4

Part numbers in this family (11)

By size:
Southwire #DescriptionConstructionStrandInsulation ThicknessGrounding ConductorDiameter Over ArmorPVC Jacket ThicknessApprox. Diameter OverallApprox. Net Weight Aluminum ArmorApprox. Net Weight Galvanized ArmorAmpacity
AAP2K6/4AAP2K6/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 6 AWG 4C6 AWG 4C78581.07501.1777892475
AAP2K4/4AAP2K4/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 4 AWG 4C4 AWG 4C78581.23501.331,0341,19595
AAP2K2/4AAP2K2/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 2 AWG 4C2 AWG 4C78561.37501.471,4691,737130
AAP2K1/4AAP2K1/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 1 AWG 4C1 AWG 4C710561.57601.691,8492,152145
AAP2K1/04AAP2K1/04 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 1/0 AWG 4C1/0 AWG 4C1910561.67601.792,2042,531170
AAP2K2/04AAP2K2/04 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 2/0 AWG 4C2/0 AWG 4C1910541.79601.912,6723,036195
AAP2K3/04AAP2K3/04 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 3/0 AWG 4C3/0 AWG 4C1910541.89602.013,1793,554225
AAP2K4/04AAP2K4/04 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 4/0 AWG 4C4/0 AWG 4C1910542.03602.153,8224,231260
AAP2K250/4AAP2K250/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 250 kcmil 4C250 kcmil 4C3712042.21602.334,5705,011290
AAP2K350/4AAP2K350/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 350 kcmil 4C350 kcmil 4C3712032.43752.586,1256,626350
AAP2K500/4AAP2K500/4 JACKETED MC RHW-2/PVC 2,000 Volt Copper 4 Conductor 500 kcmil 4C500 kcmil 4C3712022.73752.888,3168,887430

Application & features

Application

Suitable for use in industrial power distribution systems where continuity of service is the prime consideration. May be installed in wet or dry locations, directly buried, or encased in concrete. Suitable for use in cable tray. Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2.

Specifications

Voltage Rating2 kV (2,000 V)2 kV
CertificationsREACH, ROHS, UL, USAREACH, ROHS, UL, USA

Standards & references

  • UL 44, UL 854, and UL 1569
  • ICEA S-95-658/NEMA WC-70
  • Flame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU),
  • IEEE 1202/CSA FT-4, Two-hour Firewall
  • Temperature Rated at 90°C Wet/Dry
  • Sunlight Resistant, Gasoline and Oil Resistant II Jacket
  • Direct Burial (includes encasement in concrete)
  • Color Code: Black and Numbered (optional color codes available)
  • RoHS Compliant
  • NEMA BABA 70901-2-2024 WC-02-03, WC-02-04, WC-02-05