DistributorSouthwire

Service Wire

JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor

Service Wire #
SW-JACKETED-MC-2KV-3-CDRS-GALV

Three copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type RWU90) , phase identified and cabled together with suitable fillers and bare copper grounding conductor. Cable core covered with mylar binder tape and galvanized steel interlocked armour, with overall black PVC jacket. Jacket available in colours. Available with ServiceCPE ® jacket.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (12) ↓

Available sizes & constructions

Size (AWG or Kcmil)(AWG or Kcmil)Strand (no.)(no.)Insulation Thickness (mils)(mm)Grounding Conductor (AWG)(AWG)Diameter Over Armour (in.)(mm)Jacket Thickness (mils)(mm)Approx. Diameter Overall (in.)(mm)Approx. Net Weight (lb./1000')(kg/km)Ampacity (30°C ambient)(30°C ambient)
6677852.16880.9925.1501.271.0927.77651,1387575 GAP2K6/3
4477852.16661.0927.7501.271.1930.29751,4519595 GAP2K4/3
2277852.16661.2732.3501.271.3734.81,4272,124130130 GAP2K2/3
11771052.67661.4135.8501.271.5138.41,7182,557145145 GAP2K1/3
1/01/019191052.67661.5138.4601.521.6341.42,0443,042170170 GAP2K1/03
2/02/019191052.67661.6140.9601.521.7343.92,4323,619195195 GAP2K2/03
3/03/019191052.67441.7143.4601.521.8346.52,8434,231225225 GAP2K3/03
4/04/019191052.67441.8547.0601.521.9750.03,3584,997260260 GAP2K4/03
25025037371203.05442.0552.1601.522.1755.14,0386,009290290 GAP2K250/3
35035037371203.05332.2757.7751.912.4261.55,2407,798350350 GAP2K350/3
50050037371203.05222.5364.3751.912.6868.17,05010,492430430 GAP2K500/3
75075061611353.43113.0176.5852.163.1880.810,09315,020535535 GAP2K750/3

Part numbers in this family (12)

By size:
Southwire #DescriptionConstructionStrandInsulation ThicknessGrounding ConductorDiameter Over ArmourJacket ThicknessApprox. Diameter OverallApprox. Net WeightAmpacity
GAP2K6/3GAP2K6/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 6 AWG 3C6 AWG 3C78580.99501.0976575
GAP2K4/3GAP2K4/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 4 AWG 3C4 AWG 3C78561.09501.1997595
GAP2K2/3GAP2K2/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 2 AWG 3C2 AWG 3C78561.27501.371,427130
GAP2K1/3GAP2K1/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 1 AWG 3C1 AWG 3C710561.41501.511,718145
GAP2K1/03GAP2K1/03 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 1/0 AWG 3C1/0 AWG 3C1910561.51601.632,044170
GAP2K2/03GAP2K2/03 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 2/0 AWG 3C2/0 AWG 3C1910561.61601.732,432195
GAP2K3/03GAP2K3/03 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 3/0 AWG 3C3/0 AWG 3C1910541.71601.832,843225
GAP2K4/03GAP2K4/03 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 4/0 AWG 3C4/0 AWG 3C1910541.85601.973,358260
GAP2K250/3GAP2K250/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 250 kcmil 3C250 kcmil 3C3712042.05602.174,038290
GAP2K350/3GAP2K350/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 350 kcmil 3C350 kcmil 3C3712032.27752.425,240350
GAP2K500/3GAP2K500/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 500 kcmil 3C500 kcmil 3C3712022.53752.687,050430
GAP2K750/3GAP2K750/3 JACKETED MC RWU90/ACW90/ACWU90 1,000/2,000 Volt Copper 3 Conductor 750 kcmil 3C750 kcmil 3C6113513.01853.1810,093535

Application & features

Application

Suitable for use in industrial power distribution systems where continuity of service is the prime consideration. May be installed in wet or dry locations, directly buried, or encased in concrete. Suitable for use in cable tray. Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2

Specifications

Voltage Rating2 kV (2,000 V)2 kV
CertificationsCSA, Made in North America, REACH, ROHSCSA, Made in North America, REACH, ROHS

Standards & references

  • UL 44, UL 854, and UL 1569
  • ​​​​​​​CSA C22.2 #51
  • ICEA S-95-658/NEMA WC-70
  • Flame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU),
  • IEEE 1202/CSA FT-4, Two-hour Firewall
  • Temperature Rated at 90°C Wet /Dry
  • Cold Temperature Rated at -25°C
  • Sunlight and Oil Resistant II Jacket
  • Direct Burial (includes encasement in concrete)
  • Colour Code: Method 4 (optional color codes available)
  • RoHS Compliant