SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required
- Service Wire #
- SW-2KV
Single copper conductor, stranded and insulated with moisture and heat resistant, chemically crosslinked polyethylene. Featuring ServicePRO-X ® Insulation–No Pulling Lubricant Required (#6 AWG and larger) .
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (20) ↓Available sizes & constructions
| Size (AWG or Kcmil)(AWG or Kcmil) | Strand (no.)(no.) | Insulation Thickness (mils)(mm) | Nominal Diameter Overall (in.)(mm) | Approx. Net Weight (lb./1000')(kg/km) | Ampacity 90°C Wet/Dry | |
|---|---|---|---|---|---|---|
| 1414 | 77 | 601.52 | 0.194.8 | 2537 | 35†35† | RWU14BK-NPV |
| 1212 | 77 | 601.52 | 0.215.3 | 3552 | 40†40† | RWU12BK-NPV |
| 1010 | 77 | 601.52 | 0.246.1 | 4871 | 55†55† | RWU10BK-NPV |
| 88 | 77 | 802.03 | 0.307.6 | 75112 | 8080 | RWU8BK-NPV |
| 66 | 77 | 802.03 | 0.348.6 | 109162 | 105105 | RWU6BK-NPV |
| 44 | 77 | 802.03 | 0.399.9 | 162241 | 140140 | RWU4BK-NPV |
| 33 | 77 | 802.03 | 0.4110.4 | 198295 | 165165 | RWU3BK-NPV |
| 22 | 77 | 802.03 | 0.4511.4 | 249371 | 190190 | RWU2BK-NPV |
| 11 | 1919 | 952.41 | 0.5113.0 | 312464 | 220220 | RWU1BK-NPV |
| 1/01/0 | 1919 | 952.41 | 0.5714.5 | 398592 | 260260 | RWU1/0BK-NPV |
| 2/02/0 | 1919 | 952.41 | 0.5915.0 | 481716 | 300300 | RWU2/0BK-NPV |
| 3/03/0 | 1919 | 952.41 | 0.6416.3 | 595885 | 350350 | RWU3/0BK-NPV |
| 4/04/0 | 1919 | 952.41 | 0.7017.8 | 7381,098 | 405405 | RWU4/0BK-NPV |
| 250250 | 3737 | 1102.79 | 0.7619.3 | 8701,295 | 455455 | RWU250BK-NPV |
| 300300 | 3737 | 1102.79 | 0.8120.6 | 1,0311,534 | 500500 | RWU300BK-NPV |
| 350350 | 3737 | 1102.79 | 0.8621.8 | 1,1921,774 | 570570 | RWU350BK-NPV |
| 400400 | 3737 | 1102.79 | 0.9123.1 | 1,3522,012 | 615615 | RWU400BK-NPV |
| 500500 | 3737 | 1102.79 | 0.9925.1 | 1,6712,487 | 700700 | RWU500BK-NPV |
| 600600 | 6161 | 1253.17 | 1.0927.7 | 2,0122,994 | 780780 | RWU600BK-NPV |
| 750750 | 6161 | 1253.17 | 1.1729.7 | 2,4853,698 | 885885 | RWU750BK-NPV |
Part numbers in this family (20)
By size:
| Southwire # | Description | Construction | Strand | Insulation Thickness | Nominal Diameter Overall | Approx. Net Weight | Ampacity 90°C Wet/Dry | |
|---|---|---|---|---|---|---|---|---|
| RWU14BK-NPV | RWU14BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 14 AWG | 14 AWG | 7 | 60 | 0.19 | 25 | 35† | |
| RWU12BK-NPV | RWU12BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 12 AWG | 12 AWG | 7 | 60 | 0.21 | 35 | 40† | |
| RWU10BK-NPV | RWU10BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 10 AWG | 10 AWG | 7 | 60 | 0.24 | 48 | 55† | |
| RWU8BK-NPV | RWU8BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 8 AWG | 8 AWG | 7 | 80 | 0.30 | 75 | 80 | |
| RWU6BK-NPV | RWU6BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 6 AWG | 6 AWG | 7 | 80 | 0.34 | 109 | 105 | |
| RWU4BK-NPV | RWU4BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 4 AWG | 4 AWG | 7 | 80 | 0.39 | 162 | 140 | |
| RWU3BK-NPV | RWU3BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 3 AWG | 3 AWG | 7 | 80 | 0.41 | 198 | 165 | |
| RWU2BK-NPV | RWU2BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 2 AWG | 2 AWG | 7 | 80 | 0.45 | 249 | 190 | |
| RWU1BK-NPV | RWU1BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 1 AWG | 1 AWG | 19 | 95 | 0.51 | 312 | 220 | |
| RWU1/0BK-NPV | RWU1/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 1/0 AWG | 1/0 AWG | 19 | 95 | 0.57 | 398 | 260 | |
| RWU2/0BK-NPV | RWU2/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 2/0 AWG | 2/0 AWG | 19 | 95 | 0.59 | 481 | 300 | |
| RWU3/0BK-NPV | RWU3/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 3/0 AWG | 3/0 AWG | 19 | 95 | 0.64 | 595 | 350 | |
| RWU4/0BK-NPV | RWU4/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 4/0 AWG | 4/0 AWG | 19 | 95 | 0.70 | 738 | 405 | |
| RWU250BK-NPV | RWU250BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 250 kcmil | 250 kcmil | 37 | 110 | 0.76 | 870 | 455 | |
| RWU300BK-NPV | RWU300BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 300 kcmil | 300 kcmil | 37 | 110 | 0.81 | 1,031 | 500 | |
| RWU350BK-NPV | RWU350BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 350 kcmil | 350 kcmil | 37 | 110 | 0.86 | 1,192 | 570 | |
| RWU400BK-NPV | RWU400BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 400 kcmil | 400 kcmil | 37 | 110 | 0.91 | 1,352 | 615 | |
| RWU500BK-NPV | RWU500BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 500 kcmil | 500 kcmil | 37 | 110 | 0.99 | 1,671 | 700 | |
| RWU600BK-NPV | RWU600BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 600 kcmil | 600 kcmil | 61 | 125 | 1.09 | 2,012 | 780 | |
| RWU750BK-NPV | RWU750BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 750 kcmil | 750 kcmil | 61 | 125 | 1.17 | 2,485 | 885 |
Application & features
Application
Suitable for wiring in raceways, conduit, etc. Applications include general purpose wiring for power distribution, services, feeders, branch circuit wiring in residential, industrial, and commercial buildings. Suitable for use in 105°C dry systems. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade) .
Specifications
| Voltage Rating | 2 kV (2,000 V)2 kV |
|---|---|
| Certifications | CSA, REACH, ROHS, UL, USACSA, REACH, ROHS, UL, USA |
Standards & references
- ASTM Standards: B-3 (soft or annealed), B-8 (concentric lay stranded),
- B-787 (combination strand)
- UL 44 RHW-2 2kV
- ICEA S-95-658/NEMA WC-70
- Federal Spec. A-A-59544
- Flame Rated: CT Use (1/0 AWG and larger)
- Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
- Sunlight Resistant, Gasoline and Oil Resistant II
- Direct Burial
- RoHS Compliant
- NEMA BABA 70901-2-2024 WC-02-03, WC-02-04, WC-02-05