DistributorSouthwire

Service Wire

SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required

Service Wire #
SW-2KV

Single copper conductor, stranded and insulated with moisture and heat resistant, chemically crosslinked polyethylene. Featuring ServicePRO-X ® Insulation–No Pulling Lubricant Required (#6 AWG and larger) .

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (20) ↓

Available sizes & constructions

Size (AWG or Kcmil)(AWG or Kcmil)Strand (no.)(no.)Insulation Thickness (mils)(mm)Nominal Diameter Overall (in.)(mm)Approx. Net Weight (lb./1000')(kg/km)Ampacity 90°C Wet/Dry
141477601.520.194.8253735†35† RWU14BK-NPV
121277601.520.215.3355240†40† RWU12BK-NPV
101077601.520.246.1487155†55† RWU10BK-NPV
8877802.030.307.6751128080 RWU8BK-NPV
6677802.030.348.6109162105105 RWU6BK-NPV
4477802.030.399.9162241140140 RWU4BK-NPV
3377802.030.4110.4198295165165 RWU3BK-NPV
2277802.030.4511.4249371190190 RWU2BK-NPV
111919952.410.5113.0312464220220 RWU1BK-NPV
1/01/01919952.410.5714.5398592260260 RWU1/0BK-NPV
2/02/01919952.410.5915.0481716300300 RWU2/0BK-NPV
3/03/01919952.410.6416.3595885350350 RWU3/0BK-NPV
4/04/01919952.410.7017.87381,098405405 RWU4/0BK-NPV
25025037371102.790.7619.38701,295455455 RWU250BK-NPV
30030037371102.790.8120.61,0311,534500500 RWU300BK-NPV
35035037371102.790.8621.81,1921,774570570 RWU350BK-NPV
40040037371102.790.9123.11,3522,012615615 RWU400BK-NPV
50050037371102.790.9925.11,6712,487700700 RWU500BK-NPV
60060061611253.171.0927.72,0122,994780780 RWU600BK-NPV
75075061611253.171.1729.72,4853,698885885 RWU750BK-NPV

Part numbers in this family (20)

By size:
Southwire #DescriptionConstructionStrandInsulation ThicknessNominal Diameter OverallApprox. Net WeightAmpacity 90°C Wet/Dry
RWU14BK-NPVRWU14BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 14 AWG14 AWG7600.192535†
RWU12BK-NPVRWU12BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 12 AWG12 AWG7600.213540†
RWU10BK-NPVRWU10BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 10 AWG10 AWG7600.244855†
RWU8BK-NPVRWU8BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 8 AWG8 AWG7800.307580
RWU6BK-NPVRWU6BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 6 AWG6 AWG7800.34109105
RWU4BK-NPVRWU4BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 4 AWG4 AWG7800.39162140
RWU3BK-NPVRWU3BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 3 AWG3 AWG7800.41198165
RWU2BK-NPVRWU2BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 2 AWG2 AWG7800.45249190
RWU1BK-NPVRWU1BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 1 AWG1 AWG19950.51312220
RWU1/0BK-NPVRWU1/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 1/0 AWG1/0 AWG19950.57398260
RWU2/0BK-NPVRWU2/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 2/0 AWG2/0 AWG19950.59481300
RWU3/0BK-NPVRWU3/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 3/0 AWG3/0 AWG19950.64595350
RWU4/0BK-NPVRWU4/0BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 4/0 AWG4/0 AWG19950.70738405
RWU250BK-NPVRWU250BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 250 kcmil250 kcmil371100.76870455
RWU300BK-NPVRWU300BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 300 kcmil300 kcmil371100.811,031500
RWU350BK-NPVRWU350BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 350 kcmil350 kcmil371100.861,192570
RWU400BK-NPVRWU400BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 400 kcmil400 kcmil371100.911,352615
RWU500BK-NPVRWU500BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 500 kcmil500 kcmil371100.991,671700
RWU600BK-NPVRWU600BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 600 kcmil600 kcmil611251.092,012780
RWU750BK-NPVRWU750BK-NPV SERVICEPRO-X® RHW-2 or RWU90 2,000 Volt Copper, CT Rated No Pulling Lubricant Required 750 kcmil750 kcmil611251.172,485885

Application & features

Application

Suitable for wiring in raceways, conduit, etc. Applications include general purpose wiring for power distribution, services, feeders, branch circuit wiring in residential, industrial, and commercial buildings. Suitable for use in 105°C dry systems. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade) .

Specifications

Voltage Rating2 kV (2,000 V)2 kV
CertificationsCSA, REACH, ROHS, UL, USACSA, REACH, ROHS, UL, USA

Standards & references

  • ASTM Standards: B-3 (soft or annealed), B-8 (concentric lay stranded),
  • B-787 (combination strand)
  • UL 44 RHW-2 2kV
  • ICEA S-95-658/NEMA WC-70
  • Federal Spec. A-A-59544
  • Flame Rated: CT Use (1/0 AWG and larger)
  • Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
  • Sunlight Resistant, Gasoline and Oil Resistant II
  • Direct Burial
  • RoHS Compliant
  • NEMA BABA 70901-2-2024 WC-02-03, WC-02-04, WC-02-05