Copper THHN/THWN or Type TFN Insulated Copper Singles. UL Listed as Type MC and Type FPL. 600 Volt Type MC and 300 Volt Type FPL. Red Lightweight Aluminum Interlocked Armor.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (7) ↓

Available sizes & constructions

Cond. SizeConductor NumberColorDiameter Over Conductor (in)(cm)Cond. StrandsInsulation Thickness (mils)(mm)Ground SizeDiameter Over Armor (in)(cm)Approx. Weight (lbs/1000')(kgs/km)
18 AWG18 AWG440.0400.10SolidSolid200.510.5641.43100149 55501903
16 AWG16 AWG22BE,WEBE,WE0.050.13SolidSolid200.511x161x160.4051.0370104 64466503
16 AWG16 AWG440.0500.13SolidSolid200.510.6111.55124185 55502001
14 AWG14 AWG440.0640.16SolidSolid200.510.7011.78174259 55497802
14 AWG14 AWG44BK,WE,GN,BK,WEBK,WE,GN,BK,WE0.0640.16SolidSolid200.511x141x140.6911.76175260 58715102
18 AWG18 AWG443.99.916.6709.938.27012.31--1818 55501903
16 AWG16 AWG222.87.114.1816.225.0377.500.0330.05001818 64466503
16 AWG16 AWG444.310.924.1806.225.0307.49--1818 55502001
14 AWG14 AWG444.912.452.6303.913.1704.7216162020 55497802
14 AWG14 AWG444.812.192.6313.923.1704.720.0580.0916162020 58715102

Part numbers in this family (7)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
18 AWG · 4 conductors (1)
5550190318-2/18-2 DUAL TSP BK/WT/RD/BU FPL AL MC 1000 FT18 AWG 4C SOLBLACK/WHITE/RED/BLUE1000 FT REEL
16 AWG · 2 conductors (1)
6446650316-2 SOL CU TFN BLUE/WHITE/CTG SHIELDED PAIR MC FPL FIRE ALARM RED AIA 1000 FT16 AWG 2C SOLBLUE/WHITE1000 FT REEL
16 AWG · 4 conductors (2)
5550200116-4 CU TFN/TFN BLACK/WHITE/RED/BLUE AIA MC FPL TWISTED PAIR RED 250 FT16 AWG 4C SOLBLACK/WHITE/RED/BLUE250 FT COIL
5550200316-4 CU TFN/TFN BLACK/WHITE/RED/BLUE AIA MC FPL TWISTED PAIR RED 1000 FT16 AWG 4C SOLBLACK/WHITE/RED/BLUE1000 FT REEL
14 AWG · 4 conductors (2)
5549780214-2/14-2 DUAL TSP BK/WT/RD/BU FPL AL MC 250 FT14 AWG 4C SOLBLACK/WHITE/RED/BLUE250 FT COIL
5549780314-2/14-2 DUAL TSP BK/WT/RD/BU FPL AL MC 1000 FT14 AWG 4C SOLBLACK/WHITE/RED/BLUE1000 FT REEL
Other (1)
5871510214-2/14-2 SOL CU THHN TP/TSP AL MC RED FPL 1000 FT14/14 AWG 4CBLACK/WHITE/GREEN GRND/BLACK/WHITE1000 FT REEL

Application & features

Southwire Red Alert® Type MC-FPL Cable is suitable for use as follows:
- Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) & 760.135(C).
- Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devices.
- Class 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.
- Power, lighting, control, and signal circuits.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(E)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Binder tape with print legend wrapped around assembly.
- Approved for the State of Rhode Island Fire Systems.
- Rated at 600V, 90ºC dry as Type MC or 300V, 90ºC dry as Type FPL.
- Anti-short bushings are not required for use with MC cable per NEC and UL.

Southwire Red Alert® Type MC-FPL Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

Standards & references

  • UL 1424 Cables for Power-Limited Fire-Alarm Circuits
  • ASTM B3 Soft or Annealed Copper Wire
  • UL 66 Fixture Wire
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.