DistributorSouthwire

Southwire

MC-AP™ Type MC Armorlite® Type MC THHN/THWN Circuit Size Copper Conductor Neutral Per Phase

Southwire #
SPEC60240

Copper THHN Insulated Conductors. Full-Sized Aluminum Equipment Grounding/Bonding Conductor. UL Listed 600 Volt. Rated VW1. Neutral per phase. Lightweight Aluminum Interlocked Armor is Part of Equipment Bonding/Grounding Path.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (3) ↓

Available sizes & constructions

Cond. SizeConductor NumberColorDiameter Over Conductor (in)(cm)Cond. StrandsInsulation Thickness (mils)(mm)Num x Neutral SizeDiameter Over Armor (in)(cm)Approx. Weight (lbs/1000')(kgs/km)
12 AWG12 AWG22BK,RD,WE/BK,WE/RDBK,RD,WE/BK,WE/RD0.0800.20SolidSolid200.512x122x120.5381.37144214 56719101
12 AWG12 AWG2220.053.89.651.6622.472.0022.980.0540.0820202424 56719101

Part numbers in this family (3)

Southwire #DescriptionConstructionConductor ColorPackaging
12 AWG (3)
5671910112-2 SOL CU THHN 2X12NEUT BLACK/RED/WHITE-BLACK/WHITE-RED/AL GRND MCAP AIA 250 FT12 AWG 4C SOLBLK/RED/WHT-BLK/WHT-RED250 FT COIL
5671910212-2 SOL CU THHN 2X12NEUT BLACK/RED/WHITE-BLACK/WHITE-RED/AL GRND MCAP AIA 1000 FT12 AWG 4C SOLBLK/RED/WHT-BLK/WHT-RED1000 FT REEL
5671910412-2 SOL CU THHN 2X12NEUT BLACK/RED/WHITE-BLACK/WHITE-RED/AL GRND MCAP AIA 1000 FT12 AWG 4C SOLBLK/RED/WHT-BLK/WHT-RED1000 FT DRUM

Application & features

Southwire Armorlite® Type MC Cable is suitable for use as follows:
- Branch, feeder and service power distribution in commercial, industrial, institutional, and multi- residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22 (C).
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Binder tape with print legend wrapped around assembly.
- Type THHN/THWN rated 90ºC Dry.
- Neutral per phase

Southwire Armorlite® Type MC Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.