DistributorSouthwire

Southwire

DURAGROUND™ CU 600V XLPE Insulation. RHH/RHW-2/RW90 UL & CSA

Southwire #
SPEC25066

Single Copper Conductors, XLPE Insulation, Sunlight Resistant, 600V, 90°C MAX, -40°C MIN, Gasoline & Oil Resistant

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (22) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
6 AWG6 AWG11770.1770.45601.520.3000.7681121108161 64903301
2 AWG2 AWG11770.2820.72601.520.4031.02204304245365 64903901
2/0 AWG2/0 AWG1119190.4051.03802.030.5741.46410610487725 64904101
4/0 AWG4/0 AWG1119190.5121.30802.030.6661.696539727451109 64904301
350 KCMIL350 KCMIL1137370.6611.68952.410.8412.141080160712181813 64905401
500 KCMIL500 KCMIL1137370.7892.00952.410.9662.451543229617052537 64905601
750 KCMIL750 KCMIL1161610.9682.461102.791.2003.052315344525493793 64905801
1000 KCMIL1000 KCMIL1161611.1172.841102.791.3493.433087459433544991 64906001
6 AWG6 AWG111.23.0520994.800.4110.610.4950.740.0510.0865657575 64903301
2 AWG2 AWG111.64.06530240.400.1620.240.1950.290.0450.07115115130130 64903901
2/0 AWG2/0 AWG112.25.591064482.620.0810.120.0970.140.0430.06175175195195 64904101
4/0 AWG4/0 AWG112.66.601692767.480.0510.080.0620.090.0410.06230230260260 64904301
350 KCMIL350 KCMIL113.38.3828001270.060.0310.050.0390.060.0400.06310310350350 64905401
500 KCMIL500 KCMIL113.89.6540001814.370.0220.030.0290.040.0390.06380380430430 64905601
750 KCMIL750 KCMIL116.015.2460002721.550.0140.020.0220.030.0380.06475475535535 64905801
1000 KCMIL1000 KCMIL116.717.0280003628.740.0110.020.0180.030.0370.06545545615615 64906001

Part numbers in this family (22)

By size:
Southwire #DescriptionConstructionPackaging
6 AWG (3)
649033996-7 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA6 AWG 1C 7SCUT TO LENGTH REEL
649033026-7 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 5000 FT6 AWG 1C 7S5000 FT REEL
649033016-7 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 984 FT6 AWG 1C 7S984 FT REEL
2 AWG (3)
649039992-7 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA2 AWG 1C 7SCUT TO LENGTH REEL
649039022-7 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 5000 FT2 AWG 1C 7S5000 FT REEL
649039012-7 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 984 FT2 AWG 1C 7S984 FT REEL
2/0 AWG (3)
649041992/0-19 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA2/0 AWG 1C 19SCUT TO LENGTH REEL
649041022/0-19 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 5000 FT2/0 AWG 1C 19S5000 FT REEL
649041012/0-19 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 984 FT2/0 AWG 1C 19S984 FT REEL
4/0 AWG (3)
649043994/0-19 CU RHH-RHW-2 RW90 600V DURATRAY GREEN UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
649043024/0-19 CU RHH-RHW-2 RW90 600V DURATRAY GREEN UL/CSA 5000 FT4/0 AWG 1C 19S5000 FT REEL
649043014/0-19 CU RHH-RHW-2 RW90 600V DURATRAY GREEN UL/CSA 984 FT4/0 AWG 1C 19S984 FT REEL
350 kcmil (3)
64905499350-37 CU RHH-RHW-2 CSA RW90 600V GREEN350 KCMIL 1C 37SCUT TO LENGTH REEL
64905402350-37 CU RHH-RHW-2 CSA RW90 600V GREEN 5000 FT350 KCMIL 1C 37S5000 FT REEL
64905401350-37 CU RHH-RHW-2 CSA RW90 600V GREEN 984 FT350 KCMIL 1C 37S984 FT REEL
500 kcmil (3)
64905699500-37 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA500 KCMIL 1C 37SCUT TO LENGTH REEL
64905602500-37 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 5000 FT500 KCMIL 1C 37S5000 FT REEL
64905601500-37 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 984 FT500 KCMIL 1C 37S984 FT REEL
750 kcmil (2)
64905899750-61 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA750 KCMIL 1C 61SCUT TO LENGTH REEL
64905801750-61 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 984 FT750 KCMIL 1C 61S984 FT REEL
1000 kcmil (2)
649060991000-61 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA1000 KCMIL 1C 61SCUT TO LENGTH REEL
649060011000-61 CU RHH-RHW-2 RW90 600V DURAGROUND GREEN UL/CSA 984 FT1000 KCMIL 1C 61S984 FT REEL

Application & features

Suitable for installation in Cable Trays and Underground Duct Banks - As per CE Code limitations (see Rule 12-2202) for grounding and bonding applications.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • CSA SUN RES - for Sunlight Resistant rating
  • CT USE Sizes 1/0 AWG and Larger
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)