
![]()
CU Compressed 5/8kV NLEPR Insulation 133/100% IL CPE-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
- Southwire #
- SPEC46103
Type MV-105 Single Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Dual Rated UL/CSA. Silicone Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (9) ↓Available sizes & constructions
| Cond. Size | Cond. Strands | Diameter Over Conductor (in)(cm) | Diameter Over Insulation (in)(cm) | Insulation Thickness (mils)(mm) | Diameter Over Shield (in)(cm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | Max Pull Tension (lbs)(kg) | Min. Bend Radius (in)(cm) | Conduit Size (in)(cm) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 AWG2 AWG | 77 | 0.2820.72 | 0.5451.38 | 1152.92 | 0.6051.54 | 551.40 | 0.7551.92 | 458682 | 530240.40 | 9.022.86 | 2.56.35 | 55051499 |
| 1/0 AWG1/0 AWG | 1919 | 0.3610.92 | 0.6301.60 | 1152.92 | 0.6901.75 | 802.03 | 0.8702.21 | 645960 | 844382.83 | 10.426.42 | 2.56.35 | 55051599 |
| 2/0 AWG2/0 AWG | 1919 | 0.4051.03 | 0.6741.71 | 1152.92 | 0.7341.86 | 802.03 | 0.9142.32 | 7511118 | 1064482.62 | 10.927.69 | 3.07.62 | 55051699 |
| 3/0 AWG3/0 AWG | 1919 | 0.4561.16 | 0.7241.84 | 1152.92 | 0.7841.99 | 802.03 | 0.9642.45 | 8831314 | 1342608.72 | 11.529.21 | 3.07.62 | 58404699 |
| 4/0 AWG4/0 AWG | 1919 | 0.5121.30 | 0.7801.98 | 1152.92 | 0.8402.13 | 802.03 | 1.0202.59 | 10461557 | 1692767.48 | 12.230.99 | 3.07.62 | 55051899 |
| 250 KCMIL250 KCMIL | 3737 | 0.5581.42 | 0.8182.08 | 1152.92 | 0.8782.23 | 802.03 | 1.0582.69 | 11861765 | 2000907.18 | 12.632.00 | 3.07.62 | 55051999 |
| 350 KCMIL350 KCMIL | 3737 | 0.6611.68 | 0.9372.38 | 1152.92 | 0.9972.53 | 802.03 | 1.1772.99 | 15562316 | 28001270.06 | 14.135.81 | 3.58.89 | 55052099 |
| 500 KCMIL500 KCMIL | 3737 | 0.7892.00 | 1.0422.65 | 1152.92 | 1.1022.80 | 802.03 | 1.2823.26 | 20713082 | 40001814.37 | 15.338.86 | 4.010.16 | 55052199 |
| 750 KCMIL750 KCMIL | 6161 | 0.9682.46 | 1.2543.19 | 1152.92 | 1.3143.34 | 802.03 | 1.4943.79 | 29564399 | 60002721.55 | 17.945.47 | 4.511.43 | 55052299 |
| 2 AWG2 AWG | 0.1620.24 | 0.2040.30 | 0.0340.05 | 0.0440.07 | 0.389 + j0.2630.389 + j0.263 | 0.056 + j0.0450.056 + j0.045 | 19201920 | 145145 | 155155 | 190190 | 215215 | 55051499 |
| 1/0 AWG1/0 AWG | 0.1020.15 | 0.1280.19 | 0.0280.04 | 0.0420.06 | 0.389 + j0.2850.389 + j0.285 | 0.047 + j0.0400.047 + j0.040 | 21652165 | 195195 | 210210 | 260260 | 290290 | 55051599 |
| 2/0 AWG2/0 AWG | 0.0810.12 | 0.1020.15 | 0.0260.04 | 0.0400.06 | 0.389 + j0.3270.389 + j0.327 | 0.030 + j0.0320.030 + j0.032 | 23022302 | 220220 | 235235 | 300300 | 330330 | 55051699 |
| 3/0 AWG3/0 AWG | 0.0640.10 | 0.0810.12 | 0.0240.04 | 0.0390.06 | 0.389 + j0.3270.389 + j0.327 | 0.030 + j0.0320.030 + j0.032 | 24592459 | 250250 | 270270 | 345345 | 385385 | 58404699 |
| 4/0 AWG4/0 AWG | 0.0510.08 | 0.0650.10 | 0.0210.03 | 0.0380.06 | 0.390 + j0.3030.390 + j0.303 | 0.042 + j0.0410.042 + j0.041 | 26332633 | 290290 | 310310 | 400400 | 445445 | 55051899 |
| 250 KCMIL250 KCMIL | 0.0430.06 | 0.0560.08 | 0.0200.03 | 0.0370.06 | 0.390 + j0.3400.390 + j0.340 | 0.030 + j0.0330.030 + j0.033 | 28002800 | 320320 | 345345 | 445445 | 495495 | 55051999 |
| 350 KCMIL350 KCMIL | 0.0310.05 | 0.0410.06 | 0.0180.03 | 0.0350.05 | 0.390 + j0.3400.390 + j0.340 | 0.030 + j0.0330.030 + j0.033 | 31203120 | 385385 | 415415 | 550550 | 615615 | 55052099 |
| 500 KCMIL500 KCMIL | 0.0220.03 | 0.0300.04 | 0.0150.02 | 0.0330.05 | 0.390 + j0.3400.390 + j0.340 | 0.030 + j0.0330.030 + j0.033 | 35163516 | 470470 | 505505 | 695695 | 775775 | 55052199 |
| 750 KCMIL750 KCMIL | 0.0140.02 | 0.0230.03 | 0.0130.02 | 0.0320.05 | 0.390 + j0.3400.390 + j0.340 | 0.031 + j0.0340.031 + j0.034 | 41024102 | 585585 | 630630 | 900900 | 10001000 | 55052299 |
Part numbers in this family (9)
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 55051499 | 2-7 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 2 AWG 1C 7S | CUT TO LENGTH REEL | |
| 55051599 | 1/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 1/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 55051699 | 2/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 2/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 58404699 | 3/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 3/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 55051899 | 4/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 4/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 55051999 | 250-37 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 250 KCMIL 1C 37S | CUT TO LENGTH REEL | |
| 55052099 | 350-37 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 350 KCMIL 1C 37S | CUT TO LENGTH REEL | |
| 55052199 | 500-37 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 500 KCMIL 1C 37S | CUT TO LENGTH REEL | |
| 55052299 | 750-61 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA | 750 KCMIL 1C 61S | CUT TO LENGTH REEL |
Application & features
Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. Rated for 1000 lbs./FT maximum sidewall pressure.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- UL 1072 Medium-Voltage Power Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- CSA C22.2 No.230 Tray Cables - Rated TC
- CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
- CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661