DistributorSouthwire

Southwire

CU Compressed 5/8kV NLEPR Insulation 133/100% IL CPE-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46103

Type MV-105 Single Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (9) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
2 AWG2 AWG770.2820.720.5451.381152.920.6051.54551.400.7551.92458682530240.409.022.862.56.35 55051499
1/0 AWG1/0 AWG19190.3610.920.6301.601152.920.6901.75802.030.8702.21645960844382.8310.426.422.56.35 55051599
2/0 AWG2/0 AWG19190.4051.030.6741.711152.920.7341.86802.030.9142.3275111181064482.6210.927.693.07.62 55051699
3/0 AWG3/0 AWG19190.4561.160.7241.841152.920.7841.99802.030.9642.4588313141342608.7211.529.213.07.62 58404699
4/0 AWG4/0 AWG19190.5121.300.7801.981152.920.8402.13802.031.0202.59104615571692767.4812.230.993.07.62 55051899
250 KCMIL250 KCMIL37370.5581.420.8182.081152.920.8782.23802.031.0582.69118617652000907.1812.632.003.07.62 55051999
350 KCMIL350 KCMIL37370.6611.680.9372.381152.920.9972.53802.031.1772.991556231628001270.0614.135.813.58.89 55052099
500 KCMIL500 KCMIL37370.7892.001.0422.651152.921.1022.80802.031.2823.262071308240001814.3715.338.864.010.16 55052199
750 KCMIL750 KCMIL61610.9682.461.2543.191152.921.3143.34802.031.4943.792956439960002721.5517.945.474.511.43 55052299
2 AWG2 AWG0.1620.240.2040.300.0340.050.0440.070.389 + j0.2630.389 + j0.2630.056 + j0.0450.056 + j0.04519201920145145155155190190215215 55051499
1/0 AWG1/0 AWG0.1020.150.1280.190.0280.040.0420.060.389 + j0.2850.389 + j0.2850.047 + j0.0400.047 + j0.04021652165195195210210260260290290 55051599
2/0 AWG2/0 AWG0.0810.120.1020.150.0260.040.0400.060.389 + j0.3270.389 + j0.3270.030 + j0.0320.030 + j0.03223022302220220235235300300330330 55051699
3/0 AWG3/0 AWG0.0640.100.0810.120.0240.040.0390.060.389 + j0.3270.389 + j0.3270.030 + j0.0320.030 + j0.03224592459250250270270345345385385 58404699
4/0 AWG4/0 AWG0.0510.080.0650.100.0210.030.0380.060.390 + j0.3030.390 + j0.3030.042 + j0.0410.042 + j0.04126332633290290310310400400445445 55051899
250 KCMIL250 KCMIL0.0430.060.0560.080.0200.030.0370.060.390 + j0.3400.390 + j0.3400.030 + j0.0330.030 + j0.03328002800320320345345445445495495 55051999
350 KCMIL350 KCMIL0.0310.050.0410.060.0180.030.0350.050.390 + j0.3400.390 + j0.3400.030 + j0.0330.030 + j0.03331203120385385415415550550615615 55052099
500 KCMIL500 KCMIL0.0220.030.0300.040.0150.020.0330.050.390 + j0.3400.390 + j0.3400.030 + j0.0330.030 + j0.03335163516470470505505695695775775 55052199
750 KCMIL750 KCMIL0.0140.020.0230.030.0130.020.0320.050.390 + j0.3400.390 + j0.3400.031 + j0.0340.031 + j0.0344102410258558563063090090010001000 55052299

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionPackaging
550514992-7 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA2 AWG 1C 7SCUT TO LENGTH REEL
550515991/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA1/0 AWG 1C 19SCUT TO LENGTH REEL
550516992/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA2/0 AWG 1C 19SCUT TO LENGTH REEL
584046993/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA3/0 AWG 1C 19SCUT TO LENGTH REEL
550518994/0-19 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
55051999250-37 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA250 KCMIL 1C 37SCUT TO LENGTH REEL
55052099350-37 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA350 KCMIL 1C 37SCUT TO LENGTH REEL
55052199500-37 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA500 KCMIL 1C 37SCUT TO LENGTH REEL
55052299750-61 CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S BLACK CPE-TP UL/CSA750 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • CSA C22.2 No.230 Tray Cables - Rated TC
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661