DistributorSouthwire

Southwire

CU Compressed 35kV TRXLPE Insulation 133% IL Black SIM-PVC Jacket. MV 105 - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46706

Type MV-105 Single Conductor Copper, 420 Mils Tree Retardant Cross Linked Polyethylene (TRXLPE) 133% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Rated UL

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (7) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
1/0 AWG1/0 AWG19190.3610.921.2403.1542010.671.3003.30802.031.4803.7611451704844382.8317.744.964.511.43 67345899
3/0 AWG3/0 AWG19190.4561.161.3343.3942010.671.3943.54802.031.5744.00141621071342608.7218.847.754.511.43 67345699
4/0 AWG4/0 AWG19190.5121.301.3903.5342010.671.4503.68802.031.6304.14159823781692767.4819.549.534.511.43 67345599
250 KCMIL250 KCMIL37370.5581.421.4443.6742010.671.5043.821102.791.7444.43186127692000907.1820.953.095.012.70 67345499
350 KCMIL350 KCMIL37370.6611.681.5273.8842010.671.5874.031102.791.8274.642244333928001270.0621.955.635.513.97 67345399
500 KCMIL500 KCMIL37370.7892.001.6524.2042010.671.7124.351102.791.9524.962826420640001814.3723.459.445.513.97 67345299
750 KCMIL750 KCMIL61610.9682.461.8644.7342010.671.9244.891102.792.1645.503789563960002721.5525.965.796.015.24 67345199
1/0 AWG1/0 AWG0.1020.150.1280.190.0830.120.0540.080.468 + j0.4110.468 + j0.4110.102 + j0.0460.102 + j0.04640554055200200215215260260290290 67345899
3/0 AWG3/0 AWG0.0640.100.0810.120.0730.110.0500.070.466 + j0.3610.466 + j0.3610.106 + j0.0450.106 + j0.04543504350260260275275345345380380 67345699
4/0 AWG4/0 AWG0.0510.080.0650.100.0670.100.0480.070.468 + j0.4110.468 + j0.4110.102 + j0.0460.102 + j0.04645234523295295315315395395445445 67345599
250 KCMIL250 KCMIL0.0430.060.0560.080.0640.100.0480.070.467 + j0.4690.467 + j0.4690.102 + j0.0420.102 + j0.04246904690325325345345440440490490 67345499
350 KCMIL350 KCMIL0.0310.050.0410.060.0570.080.0450.070.468 + j0.4110.468 + j0.4110.102 + j0.0460.102 + j0.04650095009390390415415545545605605 67345399
500 KCMIL500 KCMIL0.0220.030.0300.040.0510.080.0430.060.467 + j0.4690.467 + j0.4690.102 + j0.0420.102 + j0.04254065406465465500500680680755755 67345299
750 KCMIL750 KCMIL0.0140.020.0230.030.0440.070.0400.060.466 + j0.3850.466 + j0.3850.102 + j0.0470.102 + j0.04759925992565565610610870870970970 67345199

Part numbers in this family (7)

By size:
Southwire #DescriptionConstructionPackaging
673458991/0-19 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL1/0 AWG 1C 19SCUT TO LENGTH REEL
673456993/0-19 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL3/0 AWG 1C 19SCUT TO LENGTH REEL
673455994/0-19 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL4/0 AWG 1C 19SCUT TO LENGTH REEL
67345499250-37 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL250 KCMIL 1C 37SCUT TO LENGTH REEL
67345399350-37 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL350 KCMIL 1C 37SCUT TO LENGTH REEL
67345299500-37 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL500 KCMIL 1C 37SCUT TO LENGTH REEL
67345199750-61 CU 420 MILS TR-XLP 35KV 133% T/S BLACK SIMpull PVC JACKET UL750 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 35KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661