DistributorSouthwire

Southwire

CU Compressed 35kV NLEPR Insulation 100% IL Black SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46701

Type MV-105 Single Conductor Copper, 345 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% Insulation Level, Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (9) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
1/0 AWG1/0 AWG19190.3610.921.0902.773458.761.1502.92802.031.3303.3810731597844382.8315.940.394.010.16 55583999
2/0 AWG2/0 AWG19190.4051.031.1342.883458.761.1943.03802.031.3743.49119517781064482.6216.441.664.010.16 55584799
3/0 AWG3/0 AWG19190.4561.161.1843.013458.761.2443.16802.031.4243.62134420001342608.7217.043.184.010.16 55585499
4/0 AWG4/0 AWG19190.5121.301.2403.153458.761.3003.30802.031.4803.76152722721692767.4817.744.964.511.43 55586299
250 KCMIL250 KCMIL37370.5581.421.2943.293458.761.3853.52802.031.5653.98174225922000907.1818.747.504.511.43 55587099
350 KCMIL350 KCMIL37370.6611.681.3973.553458.761.4573.70802.031.6374.162090311028001270.0619.649.784.511.43 55198699
500 KCMIL500 KCMIL37370.7892.001.5023.823458.761.5623.971102.791.8024.582743408240001814.3721.654.865.012.70 55588899
750 KCMIL750 KCMIL61610.9682.461.7144.353458.761.7744.511102.792.0145.123714552760002721.5524.161.216.015.24 95731699
1000 KCMIL1000 KCMIL61611.1172.841.8634.733458.761.9234.881102.792.1635.494623688080003628.7425.965.796.015.24 60899299
1/0 AWG1/0 AWG0.1020.150.1280.190.0570.080.0520.080.303 + j0.1730.303 + j0.1730.020 + j0.0390.020 + j0.03935903590200200215215260260290290 55583999
2/0 AWG2/0 AWG0.0810.120.1020.150.0530.080.0500.070.303 + j0.1730.303 + j0.1730.020 + j0.0390.020 + j0.03937273727230230245245300300330330 55584799
3/0 AWG3/0 AWG0.0640.100.0810.120.0490.070.0480.070.305 + j0.1990.305 + j0.1990.023 + j0.0330.023 + j0.03338853885260260275275345345380380 55585499
4/0 AWG4/0 AWG0.0510.080.0650.100.0460.070.0460.070.309 + j0.1740.309 + j0.1740.018 + j0.0290.018 + j0.02940584058295295315315395395445445 55586299
250 KCMIL250 KCMIL0.0430.060.0560.080.0430.060.0450.070.313 + j0.1830.313 + j0.1830.018 + j0.0330.018 + j0.03342264226325325345345440440490490 55587099
350 KCMIL350 KCMIL0.0310.050.0410.060.0390.060.0430.060.297 + j0.1580.297 + j0.1580.024 + j0.0380.024 + j0.03845454545390390415415545545605605 55198699
500 KCMIL500 KCMIL0.0220.030.0300.040.0340.050.0410.060.313 + j0.1830.313 + j0.1830.018 + j0.0330.018 + j0.03349414941465465500500680680755755 55588899
750 KCMIL750 KCMIL0.0140.020.0230.030.0290.040.0390.060.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03355275527565565610610870870970970 95731699
1000 KCMIL1000 KCMIL0.0110.020.0190.030.0260.040.0370.060.330 + j0.2090.330 + j0.2090.020 + j0.0360.020 + j0.036598959896406406906901040104011601160 60899299

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionPackaging
555839991/0-19 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA1/0 AWG 1C 19SCUT TO LENGTH REEL
555847992/0-19 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL2/0 AWG 1C 19SCUT TO LENGTH REEL
555854993/0-19 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA0 FT3/0 AWG 1C 19SCUT TO LENGTH REEL
555862994/0-19 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
55587099250-37 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL250 KCMIL 1C 37SCUT TO LENGTH REEL
55198699350-37 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA350 KCMIL 1C 37SCUT TO LENGTH REEL
55588899500-37 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA500 KCMIL 1C 37SCUT TO LENGTH REEL
95731699750-61 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA750 KCMIL 1C 61SCUT TO LENGTH REEL
608992991000-61 CU 345 MILS NL-EPR 35KV 100% T/S BLACK SIMpull PVC JACKET UL/CSA1000 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 35KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661