DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105 - 2x5 mils Tape Shield -Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46325

Type MV-105 Single Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, 2x5 Mils Tape Shield, SIMpull Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (3) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
350 KCMIL350 KCMIL37370.6611.681.1272.862205.591.1873.01802.031.3873.521861276928001270.0616.642.164.010.16 59660099
750 KCMIL750 KCMIL61610.9682.461.4643.722205.591.5243.871102.791.7844.533448513160002721.5521.454.365.012.70 58237799
1000 KCMIL1000 KCMIL61611.1172.841.6134.102205.591.6734.251102.791.9334.914339645780003628.7423.158.675.513.97 56614599
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0390.060.461 + j0.4370.461 + j0.4370.090 + j0.0340.090 + j0.03437703770390390415415550550610610 59660099
750 KCMIL750 KCMIL0.0140.020.0230.030.0210.030.0350.050.462 + j0.5040.462 + j0.5040.102 + j0.0420.102 + j0.04247524752565565610610885885990990 58237799
1000 KCMIL1000 KCMIL0.0110.020.0190.030.0190.030.0340.050.463 + j0.3510.463 + j0.3510.102 + j0.0470.102 + j0.047521452146406406906901060106011851185 56614599

Part numbers in this family (3)

By size:
Southwire #DescriptionConstructionPackaging
59660099350-37 CU 220 MILS NL-EPR 15KV 133% 2XT/S BLACK SIMpull PVC JACKET350 KCMIL 1C 37SCUT TO LENGTH REEL
58237799750-61 CU 220 MILS NL-EPR 15KV 133% 2XT/S BLACK SIMpull PVC JACKET750 KCMIL 1C 61SCUT TO LENGTH REEL
566145991000-61 CU 220 MILS NL-EPR 15KV 133% 2XT/S BLACK SIMpull PVC JACKET1000 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661