Type MV-105 Single Conductor Copper, 175 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% Insulation Level, Tape Shield, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (3) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
350 KCMIL350 KCMIL37370.6611.681.0372.631754.451.0972.79802.031.2773.241670248528001270.0615.338.863.58.89 67857999
500 KCMIL500 KCMIL37370.7892.001.1622.951754.451.2223.10802.031.4023.562208328640001814.3716.842.674.010.16 58646699
null KCMILnull KCMIL 60527955
350 KCMIL350 KCMIL0.0310.050.0410.060.0240.040.0370.060.529 + j0.4450.529 + j0.4450.162 + j0.0490.162 + j0.04934913491390390415415550550610610 67857999
500 KCMIL500 KCMIL0.0220.030.0300.040.0210.030.0350.050.472 + j0.4120.472 + j0.4120.102 + j0.0420.102 + j0.04238883888465465500500685685765765 58646699
null KCMILnull KCMIL 60527955

Part numbers in this family (3)

By size:
Southwire #DescriptionConstructionPackaging
67857999350-37 CU 175 MILS NL-EPR 15KV 100% TINNED CU T/S BLACK CPE-TP350 KCMIL 1C 37SCUT TO LENGTH REEL
58646699500-37 CU 175 MILS NL-EPR 15KV 100% T/S BLACK CPE-TP UL500 KCMIL 1C 37SCUT TO LENGTH REEL
605279551/C CU 15kV 175 NLEPR 100% SIMpull® PVC MV-1051000 KCMIL 1C 61SCUT TO LENGTH

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. Rated for 1000 lbs./FT maximum sidewall pressure. CT rated 1/0 and larger.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661