Type MC-HL Power Cable 600 or 1000 Volt Four Copper Conductor, Cross Linked Polyethylene (XLPE) Insulation Type XHHW-2, Continuous Corrugated Welded Armor - ARMOR-X®, Polyvinyl Chloride (PVC) Jacket with One Bare Copper Ground

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (17) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
8 AWG8 AWG770.1410.36451.140.8402.13501.270.9462.40476708422191.426.616.76 89052789
6 AWG6 AWG770.1770.45451.140.9202.34501.271.0262.61649966671304.367.218.29 89052889
4 AWG4 AWG770.2250.57451.141.0602.69501.271.1662.9691813661068484.448.220.83 89052999
2 AWG2 AWG770.2820.72451.141.2203.10601.521.3263.37129519271698770.209.323.62 89053089
1/0 AWG1/0 AWG19190.3610.92551.401.4703.73601.521.5764.001948289927031226.0611.027.94 89053199
2/0 AWG2/0 AWG19190.4051.03551.401.5403.91601.521.6664.232437362734071545.3911.729.72 89053299
3/0 AWG3/0 AWG19190.4561.16551.401.7604.47601.521.8864.792954439642951948.1813.233.53 58226599
4/0 AWG4/0 AWG19190.5121.30551.401.8454.69601.521.9715.013536526254162456.6513.835.05 89053399
250 KCMIL250 KCMIL37370.5581.42651.652.0405.18601.522.1665.504278636664002902.9915.238.61 89053499
350 KCMIL350 KCMIL37370.6611.68651.652.2905.82751.912.4486.225741854489604064.1817.143.43 89053589
500 KCMIL500 KCMIL37370.7892.00651.652.6706.78751.912.8287.18798011876128005805.9819.850.29 89053699
600 KCMIL600 KCMIL61610.8402.13802.032.8807.32751.913.0387.72919413682153606967.1721.354.10 59272799
750 KCMIL750 KCMIL61610.9682.46802.033.2208.18852.163.3988.631225418236192008708.9723.860.45 89053799
8 AWG8 AWG0.6530.970.7861.170.0330.050.0520.08 89052789
6 AWG6 AWG0.4110.610.4950.740.0270.040.0510.08 89052889
4 AWG4 AWG0.2580.380.3100.460.0220.030.0480.07 89052999
2 AWG2 AWG0.1620.240.1950.290.0180.030.0450.07 89053089
1/0 AWG1/0 AWG0.1020.150.1220.180.0170.030.0440.07 89053199
2/0 AWG2/0 AWG0.0810.120.0970.140.0160.020.0430.06 89053299
3/0 AWG3/0 AWG0.0640.100.0780.120.0140.020.0420.06 58226599
4/0 AWG4/0 AWG0.0510.080.0620.090.0130.020.0410.06 89053399
250 KCMIL250 KCMIL0.0430.060.0530.080.0140.020.0410.06 89053499
350 KCMIL350 KCMIL0.0310.050.0390.060.0120.020.0400.06 89053589
500 KCMIL500 KCMIL0.0220.030.0290.040.0100.010.0390.06 89053699
600 KCMIL600 KCMIL0.0180.030.0260.040.0100.010.0340.05 59272799
750 KCMIL750 KCMIL0.0140.020.0220.030.0100.010.0380.06 89053799

Part numbers in this family (17)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
8 AWG (2)
890527998-7 4/C CPRESS CU XHHW-2 1X#10 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET8 AWG 4C 7SBLACK/RED/BLUE/ORANGE/10 AWG BARE GRNDCUT TO LENGTH REEL
890527898-7 4/C CPRESS CU XHHW-2 1X#10 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET 5000 FT8 AWG 4C 7SBLACK/RED/BLUE/ORANGE/10 AWG BARE GRND5000 FT REEL
6 AWG (2)
890528996-7 4/C CPRESS CU XHHW-2 1X#8 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET6 AWG 4C 7SBLACK/RED/BLUE/ORANGE/8 AWG BARE GRNDCUT TO LENGTH REEL
890528896-7 4/C CPRESS CU XHHW-2 1X#8 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET 5000 FT6 AWG 4C 7SBLACK/RED/BLUE/ORANGE/8 AWG BARE GRND5000 FT REEL
4 AWG (1)
890529994-7 4/C CPRESS CU XHHW-2 1X#8 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET4 AWG 4C 7 STR1-BLACK/2-RED/3-BLUE/4-ORANGE/8 AWG BARE GRNDCUT TO LENGTH REEL
2 AWG (2)
890530992-7 4/C CPRESS CU XHHW-2 1X#6 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET2 AWG 4C 7 STR1-BLACK/2-RED/3-BLUE/4-ORANGE/6 AWG BARE GRNDCUT TO LENGTH REEL
890530892-7 4/C CPRESS CU XHHW-2 1X#6 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET 3000 FT2 AWG 4C 7 STR1-BLACK/2-RED/3-BLUE/4-ORANGE/6 AWG BARE GRND3000 FT REEL
1/0 AWG (1)
890531991/0-19 4/C CPRESS CU XHHW-2 1X#6 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET1/0 AWG 4C 19S1-BLACK/2-RED/3-BLUE/4-ORANGE/6 AWG BARE GRNDCUT TO LENGTH REEL
2/0 AWG (1)
890532992/0-19 4/C CPRESS CU XHHW-2 1X#4 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET2/0 AWG 4C 19 STR1-BLACK/2-RED/3-BLUE/4-ORANGE/4 AWG BARE GRNDCUT TO LENGTH REEL
3/0 AWG (1)
582265993/0-19 4/C CPRESS CU XHHW-2 1X#4 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET3/0 AWG 4C 19S1-BLACK/2-RED/3-BLUE/4-ORANGE/4 AWG BARE GRNDCUT TO LENGTH REEL
4/0 AWG (1)
890533994/0-19 4/C CPRESS CU XHHW-2 1X#4 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET4/0 AWG 4C 19 STR1-BLACK/2-RED/3-BLUE/4-ORANGE/4 AWG BARE GRNDCUT TO LENGTH REEL
250 kcmil (1)
89053499250-37 4/C CPRESS CU XHHW-2 1X#4 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET250 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGE/4 AWG BARE GRNDCUT TO LENGTH REEL
350 kcmil (2)
89053599350-37 4/C CPRESS CU XHHW-2 1X#3 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET350 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGE/3 AWG BARE GRNDCUT TO LENGTH REEL
89053589350-37 4/C CPRESS CU XHHW-2 1X#3 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET 1500 FT350 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGE/3 AWG BARE GRND1500 FT REEL
500 kcmil (1)
89053699500-37 4/C CPRESS CU XHHW-2 1X#2 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET 0 FT500 KCMIL 4C 37S1-BLACK/2-RED/3-BLUE/4-ORANGE/2 AWG BARE GRNDCUT TO LENGTH REEL
600 kcmil (1)
59272799600-61 4/C CPRESS CU XHHW-2 1X#2 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET600 KCMIL 4C 61S1-BLACK/2-RED/3-BLUE/4-ORANGE/2 AWG BARE GRNDCUT TO LENGTH REEL
750 kcmil (1)
89053799750-61 4/C CPRESS CU XHHW-2 1X#1 CU GW ARMOR-X MC-HL CSA RA90-HL 600V BLACK PVC JACKET750 KCMIL 4C 61S1-BLACK/2-RED/3-BLUE/4-ORANGE/1 AWG BARE GRNDCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt Type MC-HL ARMOR-X® power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)