DistributorSouthwire

Southwire

CU 2000V XLPE Insulation Three Grounds Cu Tape Shield PVC Jacket. RHH/RHW-2 Variable Frequency Drive (VFD)

Southwire #
SPEC45451

Type TC-ER VFD Power Cable 2000 Volt Three Conductor Copper, Cross Linked Polyethylene (XLPE) insulation RHH/RHW-2 Polyvinyl Chloride (PVC) Jacket with 3 Symmetrical Bare CU Ground 50% Minimum Tape Shield Overlap. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (17) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
14 AWG14 AWG33770.070.18601.520.4511.15601.520.5711.4593138202301 58067299
12 AWG12 AWG33770.0880.22601.520.4861.23601.520.6061.54128190244363 58068599
10 AWG10 AWG33770.1130.29601.520.5371.36601.520.6571.67183272329490 58069399
8 AWG8 AWG33770.1410.36701.780.6521.66601.520.7721.96270402456679 56938899
6 AWG6 AWG33770.1770.45701.780.7231.84802.030.8832.24389579624929 58070199
4 AWG4 AWG33770.2250.57701.780.8252.10802.030.9852.505478148151213 56938999
2 AWG2 AWG33770.2820.72701.780.9462.40802.031.1062.81827123111211668 56938799
1 AWG1 AWG3319190.3220.82952.411.3163.34802.031.2723.231065158515082244 67736799
1/0 AWG1/0 AWG3319190.3610.92902.291.2203.10802.031.3803.511373204318582765 64433399
2/0 AWG2/0 AWG3319190.4051.03902.291.3113.33802.031.4713.741640244121643220 64433499
3/0 AWG3/0 AWG3319190.4561.16902.291.4193.60802.031.5794.012041303726043875 64433799
4/0 AWG4/0 AWG3319190.5121.30902.291.5063.831152.921.7364.412542378332024765 64433899
250 KCMIL250 KCMIL3337370.5581.421052.671.6654.231152.921.8954.813150468839955945 64433999
350 KCMIL350 KCMIL3337370.6611.681052.671.8794.771152.922.1095.364110611650987587 64434099
500 KCMIL500 KCMIL3337370.7892.001052.672.1495.461152.922.3796.0457068491676710070 64434199
600 KCMIL600 KCMIL3361610.8652.201203.052.4096.121152.922.6396.7066739931802511943 66909999
14 AWG14 AWG336.917.539844.452.6313.9220202525 58067299
12 AWG12 AWG337.318.5415670.761.6622.472.0022.980.0570.080.0540.0825253030 58068599
10 AWG10 AWG337.920.07249112.941.0401.551.2531.860.0490.070.0500.0735354040 58069399
8 AWG8 AWG339.323.62396179.620.6530.970.7861.170.0460.070.0520.0850505555 56938899
6 AWG6 AWG3310.626.92629285.310.4110.610.4950.740.0390.060.0510.0865657575 58070199
4 AWG4 AWG3311.829.971001454.050.2580.380.3100.460.0320.050.0480.0785859595 56938999
2 AWG2 AWG3313.333.781592722.120.1620.240.1950.290.0270.040.0450.07115115130130 56938799
1 AWG1 AWG3315.338.862009911.270.1290.190.1670.250.0320.050.0320.05130130145145 67736799
1/0 AWG1/0 AWG3316.642.1625341149.400.1020.150.1220.180.0270.040.0440.07150150170170 64433399
2/0 AWG2/0 AWG3317.744.9631941448.770.0810.120.0970.140.0250.040.0430.06175175195195 64433499
3/0 AWG3/0 AWG3318.948.0140271826.610.0640.100.0780.120.0220.030.0420.06200200225225 64433799
4/0 AWG4/0 AWG3320.852.8350782303.340.0510.080.0620.090.0200.030.0410.06230230260260 64433899
250 KCMIL250 KCMIL3322.757.6660002721.550.0430.060.0530.080.0210.030.0410.06255255290290 64433999
350 KCMIL350 KCMIL3325.364.2684003810.170.0310.050.0390.060.0180.030.0400.06310310350350 64434099
500 KCMIL500 KCMIL3328.572.39120005443.100.0220.030.0290.040.0160.020.0390.06380380430430 64434199
600 KCMIL600 KCMIL3331.780.52144006531.720.0180.030.0250.040.0160.020.0390.06420420475475 66909999

Part numbers in this family (17)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
14 AWG (1)
5806729914-7 3/C CU RHH-RHW-2 3x18 GW T/S PVC JKT TC-ER 2000V VFD14 AWG 3C 7 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
12 AWG (1)
5806859912-7 3/C CU RHH-RHW-2 3x16 GW T/S PVC JKT TC-ER 2000V VFD12 AWG 3C 7S1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
10 AWG (1)
5806939910-7 3/C CU RHH-RHW-2 3x14 GW T/S PVC JKT TC-ER 2000V VFD10 AWG 3C 7 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
8 AWG (1)
569388998-7 3/C CU RHH-RHW-2 3X#14 GW T/S PVC JKT TC-ER 2000V VFD8 AWG 3C 7 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
6 AWG (1)
580701996-7 3/C CU RHH-RHW-2 3X#12 GW T/S PVC JKT TC-ER 2000V VFD6 AWG 3C 7 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
4 AWG (1)
569389994-7 3/C CU RHH-RHW-2 3X#12 GW T/S PVC JKT TC-ER 2000V VFD4 AWG 3C 7 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
2 AWG (1)
569387992-7 3/C CU RHH-RHW-2 3X#10 GW T/S PVC JKT TC-ER 2000V VFD2 AWG 3C 7 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
1 AWG (1)
677367991-19 CU 3/C RHW-2 M4 PHID 3x8GW CU T/S PVC JKT TC POWER CABLE 2000V VFD1 AWG 3C 19 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
1/0 AWG (1)
644333991/0-19 3/C CU RHH-RHW-2 3X#6 GW T/S PVC JKT TC-ER 2000V VFD1/0 AWG 3C 19 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
2/0 AWG (1)
644334992/0-19 3/C CU RHH-RHW-2 3X#6 GW T/S PVC JKT TC-ER 2000V VFD2/0 AWG 3C 19 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
3/0 AWG (1)
644337993/0-19 3/C CU RHH-RHW-2 3X#4 GW T/S PVC JKT TC-ER 2000V VFD3/0 AWG 3C 19 STRBLACK/BLACK/BLACKCUT TO LENGTH REEL
4/0 AWG (1)
644338994/0-19 3/C CU RHH-RHW-2 3X#4 GW T/S PVC JKT TC-ER 2000V VFD4/0 AWG 3C 19 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
250 kcmil (1)
64433999250-37 3/C CU RHH-RHW-2 3X#2 GW T/S PVC JKT TC-ER 2000V VFD250 KCMIL 3C 37S1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
350 kcmil (2)
64434099350-37 3/C CU RHH-RHW-2 3X#2 GW T/S PVC JKT TC-ER 2000V VFD350 KCMIL 3C 37 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
66892199350-37 3/C CU RHH-RHW-2 3X#3 GW T/S PVC JKT TC-ER 2000V VFD350 KCMIL 3C 37 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
500 kcmil (1)
64434199500-37 3/C CU RHH-RHW-2 3X#1 GW T/S PVC JKT TC-ER 2000V VFD500 KCMIL 3C 37SBLACK/BLACK/BLACKCUT TO LENGTH REEL
600 kcmil (1)
66909999600-61 3/C CU RHH-RHW-2 3X#1 GW T/S PVC JKT TC-ER 2000V VFD600 KCMIL 3C 61S1-BLACK/2-RED/3-BLUECUT TO LENGTH REEL

Application & features

Southwire’s 2000 Volt Type TC-ER VFD power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Type (TC-ER) per NEC 336.10.

Gland Reference: Glands

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • ICEA S-138-738 Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661