Access Control Cable, Riser
- Southwire #
- GEN37
Genesis® Access Control Cables simplify and expedite wiring of access points by combining individual lock power, door contact, card reader, and request-to-exit cables into a single, easy-to-pull bundle.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (7) ↓Available sizes & constructions
| Size (AWG or kcmil)(mm2) | Number of Conductors | Shielding | Size (AWG) | No. of Conductors | Shielding | Size (AWG) | No. of Conductors | Shielding | Size (AWG) | No. of Conductors | Shielding | Building Type | Nom. OD (mils)(mm) | Nominal Total Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 22 AWG22 AWG | 66 | ShieldedShielded | 1818 | 44 | UnshieldedUnshielded | 2222 | 22 | UnshieldedUnshielded | 2222 | 44 | UnshieldedUnshielded | Profusion® UnjacketedProfusion® Unjacketed | 3488.84 | 71106 | 21951099 |
Part numbers in this family (7)
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 22 AWG (7) | ||||
| 21951099 | 18(4)+22(2+4+6)1S CL3R/FPLR/CMR GENESIS PROFUSION 1000 FT | 22 AWG 4C 7 STR | 1000 FT REEL | |
| 21955099 | 18(4)+22(2+4+6)1S CL3R/FPLR/CMR GENESIS PROFUSION 500 FT | 22 AWG 4C 7 STR | 500 FT REEL | |
| 21961002 | 18(4)+22(2+4+6)1S CL3R/FPLR/CMR YELLOW GENESIS ACCESS CONTROL OAJ 1000 FT | 22 AWG 4C 7 STR | 1000 FT REEL | |
| 21965002 | 18(4)+22(2+4+6)1S CL3R/FPLR/CMR YELLOW GENESIS ACCESS CONTROL OAJ 500 FT | 22 AWG 4C 7 STR | 500 FT REEL | |
| 22951099 | 18(4)+22(2+4+6)4S CL3R/FPLR/CMR GENESIS PROFUSION 1000 FT | 22 AWG 4C 7 STR | 1000 FT REEL | |
| 22955099 | 18(4)+22(2+4+6)4S CL3R/FPLR/CMR GENESIS PROFUSION 500 FT | 22 AWG 4C 7 STR | 500 FT REEL | |
| 22965002 | 18(4)+22(2+4+6)4S CL3R/FPLR/CMR YELLOW GENESIS ACCESS CONTROL OAJ 500 FT | 22 AWG 4C 7 STR | 500 FT REEL | |
Application & features
Genesis® Riser Rated Access Control Cable is suitable for installation as follows:
- Installed in a metal raceway that complies with 300.22(B).
- Supported by solid bottom metal cable trays with solid metal covers.
- In risers.
- Within buildings in other than air-handling spaces and risers.
- Exposed to sunlight.
Standards & references
- UL 1666 - Riser Rated
- CSA C22.2 No. 2556 - FT4 Rated
- UL 444 - Communication Cables, Type CMR
- UL 1424 - Cables for Power-Limited Fire-Alarm Circuits, Type FPLR
- UL 13 - Power-Limited Circuit Cables, Type CL3R
- Sunlight Resistant Rated
- REACH/RoHS Compliant