DistributorSouthwire

Southwire

Access Control Cable, Plenum

Southwire #
GEN36

Genesis® Access Control Cables simplify and expedite wiring of access points by combining individual lock power, door contact, card reader, and request-to-exit cables into a single, easy-to-pull bundle.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (10) ↓

Available sizes & constructions

Size (AWG or kcmil)(mm2)Number of ConductorsShieldingSize (AWG)No. of ConductorsShieldingSize (AWG)No. of ConductorsShieldingSize (AWG)No. of ConductorsShieldingBuilding TypeNom. OD (mils)(mm)Nominal Total Weight (lbs/1000')(kgs/km)
22 AWG22 AWG66ShieldedShielded181844UnshieldedUnshielded222222UnshieldedUnshielded222244UnshieldedUnshieldedProfusion® UnjacketedProfusion® Unjacketed3458.7677115 31951099

Part numbers in this family (10)

Southwire #DescriptionConstructionPackaging
22 AWG (10)
3195109918(4)+22(2+4+6)1S CMP/CL3P/FPLP GENESIS PROFUSION 1000 FT22 AWG 4C 7 STR1000 FT REEL
3195509918(4)+22(2+4+6)1S CMP/CL3P/FPLP GENESIS PROFUSION 500 FT22 AWG 4C 7 STR500 FT REEL
3196100118(4)+22(2+4+6)1S CMP/CL3P/FPLP WHITE GENESIS ACCESS CONTROL OAJ 1000 FT22 AWG 4C 7 STR1000 FT REEL
3196500118(4)+22(2+4+6)1S CMP/CL3P/FPLP WHITE GENESIS ACCESS CONTROL OAJ 500 FT22 AWG 4C 7 STR500 FT REEL
3196100218(4)+22(2+4+6)1S CMP/CL3P/FPLP YELLOW GENESIS ACCESS CONTROL OAJ 1000 FT22 AWG 4C 7 STR1000 FT REEL
3196500218(4)+22(2+4+6)1S CMP/CL3P/FPLP YELLOW GENESIS ACCESS CONTROL OAJ 500 FT22 AWG 4C 7 STR500 FT REEL
3295109918(4)+22(2+4+6)4S CMP/CL3P/FPLP GENESIS PROFUSION 1000 FT22 AWG 4C 7 STR1000 FT REEL
3295509918(4)+22(2+4+6)4S CMP/CL3P/FPLP GENESIS PROFUSION 500 FT22 AWG 4C 7 STR500 FT REEL
3296100218(4)+22(2+4+6)4S CMP/CL3P/FPLP YELLOW GENESIS ACCESS CONTROL OAJ 1000 FT22 AWG 4C 7 STR1000 FT REEL
3296500218(4)+22(2+4+6)4S CMP/CL3P/FPLP YELLOW GENESIS ACCESS CONTROL OAJ 500 FT22 AWG 4C 7 STR500 FT REEL

Application & features

Genesis® Plenum Rated Access Control Cable is suitable for installation as follows:

  • In fabricated ducts as described in NEC 300.22(B).
  • In other spaces used for environmental air as described in NEC 300.22(C).
  • In risers.
  • Within buildings in other than air-handling spaces and risers.

Standards & references

  • NFPA 262 - Plenum Rated
  • CSA C22.2 No. 2556 - FT6 Rated
  • UL 444 - Communication Cables, Type CMP
  • UL 1424 - Cables for Power-Limited Fire-Alarm Circuits, Type FPLP
  • UL 13 - Power-Limited Circuit Cables, Type CL3P
  • REACH/RoHS Compliant