DistributorSouthwire

Southwire

600V CU EPR TRIADS CPE STOS Instrumentation

Southwire #
SPEC43624

Type TC-ER Instrumentation Cable 600 Volt Tinned Copper Conductors EPR Insulated Singles Shielded Triads with Overall Shield STOS. CPE Jacket Heat, Moisture, Oil and Sunlight Resistant. Rated for -30°C to 90°C

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (2) ↓

Available sizes & constructions

Cond. SizeConductor NumberDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Min. Bend Radius (in)(cm)DC Resistance at 25C (ohms/1000')(ohms/km)
16 AWG16 AWG880.0560.14300.76802.030.9642.4552478011.629.464.1816.22 59548299
16 AWG16 AWG440.0560.14300.76601.520.7501.912774129.022.864.1816.22 59548199
181840.6640.660.09570.0957
161648.5148.510.08950.0895

Part numbers in this family (2)

By size:
Southwire #DescriptionConstructionPackaging
5954829916-7 TINNED CU UNLISTED/CPE STOS TC BLACK16 AWG 0C 7SCUT TO LENGTH REEL
5954819916/4 TRIAD STR TINNED CU UNLISTED/CPE STOS TC BLACK16 AWG 12C 7SCUT TO LENGTH REEL

Application & features

Southwire’s Instrumentation Cables Type TC-ER per UL 1277 are suitable for installations as outlined in NEC Article 336 for process control and instrumentation, control circuits for operation and interconnection of protective and signaling devices and for general use in manufacturing, industrial and commercial distribution systems. Cables are constructed with 7-strand tinned copper conductors insulated with Ethylene Propylene Rubber EPR. The triad conductors are colored black, white, red and alpha-numeric printed. Each pair has an aluminum polyester foil with 100% coverage and a tinned drain wire. The overall assembly is covered with an aluminum polyester foil with 100% coverage and a tinned drain wire. The cable is suited for use in cable trays, raceways, conduit, aerial (when supported with a messenger) and direct burial. The cable is rated for -30°C to 90°C wet or dry and rated for Class I Div II hazardous locations, sun and oil resistant. The jacket is black Chlorinated Polyeth- ylene CPE with a rip cord for easy removal

Standards & references

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method