28KV Aluminum XLP MV LLDPE Jacket
- Southwire #
- MVDIST3
Aluminum Conductor. TRXLP Insulation. Bare Copper Concentric Neutrals. Low Density Polyethylene Jacket.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (6) ↓Available sizes & constructions
| No. of Conductors | Size (AWG or kcmil)(mm2) | No. of Strands | Insulation Thickness (mils)(mm) | Nom. OD (mils)(mm) | Nominal Total Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|
| 11 | 1/0 AWG1/0 AWG | 1818 | 2807.11 | 124431.60 | 7601131 | |
| 11 | 1/0 AWG1/0 AWG | 1919 | 2807.11 | 126032.01 | 7741152 | 60689225 |
| 11 | 2/0 AWG2/0 AWG | 1818 | 2807.11 | 128432.62 | 7981187 | |
| 11 | 500 KCMIL500 KCMIL | 3737 | 2807.11 | 178145.24 | 16382438 | 60689325 |
| 11 | 750 KCMIL750 KCMIL | 6161 | 2807.11 | 203351.65 | 22693376 | 60689425 |
| 11 | 1000 KCMIL1000 KCMIL | 6161 | 2807.11 | 216755.06 | 27554100 |
Part numbers in this family (6)
By size:
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 1/0 AWG (2) | ||||
| 60689225 | 1/0-19 MB CPRESS AL 28KV 280 mils 100% TRXLP 90C 16x14CN POLY JACKET/RED STRIPE | 1/0 AWG 1C 19S | 2500 FT REEL | |
| 66299801 | 1/0-19 MB CPRESS AL SUPER SMOOTH 28KV 280 mils 100% TRXLP 90C 16x14CN HiDri Plus POLY JACKET - CITY OF JACKSONVILLE BEACH 00981 | 1/0 AWG 1C 19S | 2000 FT REEL | |
| 500 kcmil (2) | ||||
| 60689326 | 500-37 MB CPRESS AL 28KV 280 mils 100% TRXLP 90C 25x14CN POLY JACKET/RED STRIPE | 500 KCMIL 1C 37S | 1500 FT REEL | |
| 60689325 | 500-37 MB CPRESS AL 28KV 280 mils 100% TRXLP 90C 25x14CN POLY JACKET/RED STRIPE | 500 KCMIL 1C 37S | 2500 FT REEL | |
| 750 kcmil (2) | ||||
| 60689426 | 750-61 MB CPRESS AL 28KV 280 mils 100% TRXLP 90C 24x12CN POLY JACKET/RED STRIPE | 750 KCMIL 1C 61S | 1500 FT REEL | |
| 60689425 | 750-61 MB CPRESS AL 28KV 280 mils 100% TRXLP 90C 24x12CN POLY JACKET/RED STRIPE | 750 KCMIL 1C 61S | 2500 FT REEL | |
Application & features
Predominantly used for primary underground distribution in conduit systems suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 28,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.
Standards & references
- B231: Aluminum 1350 Conductors, Concentric-Lay-Stranded
- B609: Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
- B3: Soft Annealed Copper Wire
- ICEA S-94-649
- AEIC CS-8
- RUS U-1
- CSA