25KV Copper XLP MV LLDPE Jacket
- Southwire #
- MVDIST34
Copper Conductor. TRXLP Insulation. Bare Copper Concentric Neutrals. Low Density Polyethylene Jacket.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (13) ↓Available sizes & constructions
| No. of Conductors | Size (AWG or kcmil)(mm2) | No. of Strands | Insulation Thickness (mils)(mm) | Nom. OD (mils)(mm) | Nominal Total Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|
| 11 | 1 AWG1 AWG | 1919 | 2606.60 | 119030.23 | 9321387 | |
| 11 | 1/0 AWG1/0 AWG | 1919 | 2606.60 | 123031.25 | 8921328 | |
| 11 | 2/0 AWG2/0 AWG | 1919 | 2606.60 | 127432.36 | 10281529 | 62821199 |
| 11 | 4/0 AWG4/0 AWG | 1919 | 2606.60 | 140035.57 | 14402143 | 62821599 |
| 11 | 350 KCMIL350 KCMIL | 3737 | 2606.60 | 159240.45 | 21373180 | 62821899 |
| 11 | 500 KCMIL500 KCMIL | 3737 | 2606.60 | 181646.15 | 29694418 | 62822199 |
| 11 | 750 KCMIL750 KCMIL | 6161 | 2606.60 | 200550.95 | 41376156 | 62822599 |
| 11 | 1000 KCMIL1000 KCMIL | 6161 | 2606.60 | 214254.42 | 45696800 | 40516702 |
Part numbers in this family (13)
By size:
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 1/0 AWG (2) | ||||
| 62826999 | 1/0-19 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 16x12CN POLY JACKET/RED STRIPE | 1/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 62820899 | 1/0-19 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 9x14CN POLY JACKET/RED STRIPE | 1/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 2/0 AWG (2) | ||||
| 62821199 | 2/0-19 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 11x14CN POLY JACKET/RED STRIPE | 2/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 62827299 | 2/0-19 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 13x10CN POLY JACKET/RED STRIPE | 2/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 4/0 AWG (2) | ||||
| 62821599 | 4/0-19 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 18x14CN POLY JACKET/RED STRIPE | 4/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 62827499 | 4/0-19 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 20x10CN POLY JACKET/RED STRIPE | 4/0 AWG 1C 19S | CUT TO LENGTH REEL | |
| 350 kcmil (1) | ||||
| 62821899 | 350-37 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 18x12CN POLY JACKET/RED STRIPE | 350 KCMIL 1C 37S | CUT TO LENGTH REEL | |
| 500 kcmil (1) | ||||
| 62822199 | 500-37 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 17x10CN POLY JACKET/RED STRIPE | 500 KCMIL 1C 37S | CUT TO LENGTH REEL | |
| 750 kcmil (1) | ||||
| 62822599 | 750-61 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 25x10CN POLY JACKET/RED STRIPE | 750 KCMIL 1C 61S | CUT TO LENGTH REEL | |
| 1000 kcmil (4) | ||||
| 62823599 | 1000-61 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 21x8CN POLY JACKET/RED STRIPE | 1000 KCMIL 1C 61S | CUT TO LENGTH REEL | |
| 62823399 | 1000-61 MB CPRESS CU 25KV 260 mils 100% TRXLP 90C 26x9CN POLY JACKET/RED STRIPE | 1000 KCMIL 1C 61S | CUT TO LENGTH REEL | |
| 40516702 | 1000-61 MB CPRESS CU SUPER SMOOTH 25KV 260 mils 100% TRXLP 90C 16x12CNPOLY JACKET - ONCOR (TXU ) 311631 | 1000 KCMIL 1C 61S | 1400 FT REEL | |
| 60687825 | 1000-61 MB CPRESS CU SUPER SMOOTH 25KV 260 mils 100% TRXLP 90C 8 LCS POLY JACKET/RED STRIPE | 1000 KCMIL 1C 61S | 1000 FT REEL | |
Application & features
Predominantly used for primary underground distribution in conduit systems suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 25,000 volts or less and at conductor temperatures not to exceed 90°C for normal operation.
Standards & references
- B3: Soft Annealed Copper Wire
- B8: Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft
- ICEA S-94-649
- AEIC CS-8
- RUS U-1